C. Installation of Plywood:<br />

1. General: Comply with applicable recommendations contained in Form No. E<br />

304 "APA Design/<strong>Construction</strong> Guide - Residential & Commercial" for types of<br />

plywood products <strong>and</strong> applications indicated.<br />

2. Apply sheathing with long dimension (face grain) perpendicular to framing.<br />

Apply with side edges 1/4 inch apart <strong>and</strong> end edges 1/8 inch apart. All end<br />

edges of sheathing shall bear on a support. Stagger end joints of roof<br />

sheathing.<br />

3. For wood framing, nail to supports with 6d common nails spaced 6 inches on<br />

center along edges <strong>and</strong> 12 inches on center at intermediate supports.<br />

4. Use 11 gauge galvanized roofing nails 1-3/4" inches long with 7/16 inch heads<br />

for wood framing. Fasteners shall be installed at 6" o.c. on panel edges, at<br />

12" o.c. along intermediate supports, <strong>and</strong> 3/8" minimum from panel edge.<br />

END OF SECTION<br />

MAHG121038 06 10 00 - 5 ROUGH CARPENTRY