SECTION 09 22 16 – NON-STRUCTURAL METAL FRAMING<br />

PART 1 – GENERAL<br />

1.1 SUMMARY<br />

1.2 SUBMITTALS<br />

A. This Section includes the following:<br />

1. Interior framing systems (includes but is not limited to supports for partition<br />

walls, framed soffits, furring).<br />

2. Interior suspension systems (includes but is not limited to supports for<br />

ceilings, suspended soffits).<br />

B. Related Sections include the following:<br />

1. Division 6 Section “Rough Carpentry”<br />

2. Division 9 Section “Gypsum Board”<br />

A. Product Data: For each type of product indicated.<br />

1.3 QUALITY ASSURANCE<br />

A. Direct Suspension Systems: ASTM C635<br />

B. Metal Support System Installation: ASTM C754<br />

C. Allowable Tolerances: 1/8" in 8' - 0" variation in finish surface<br />

1.4 DELIVERY, STORAGE, AND HANDLING<br />

A. Store materials inside under cover <strong>and</strong> in a manner to keep them dry, protected<br />

from weather, direct sunlight, surface contamination, corrosion <strong>and</strong> damage from<br />

construction traffic <strong>and</strong> other causes.<br />

PART 2 – PRODUCTS<br />

2.1 NON-LOAD-BEARING STEEL FRAMING, GENERAL<br />

A. Framing Members, General: Comply with ASTM C 754 for conditions indicated.<br />

1. Steel Sheet Components: Comply with ASTM C 645 requirements for metal,<br />

unless otherwise indicated.<br />

MAHG121038 09 22 16 - 1 NON-STRUCTURAL METAL FRAMING