2. Provide “retention clips” at all areas of Type 2 (equal to Armstrong 414).<br />

2.2 CEILING SUSPENSION MATERIALS<br />

A. General: Comply with ASTM C635, as applicable to type of suspension system<br />

required for type of ceiling units indicated. Coordinate with other work supported<br />

by or penetrating through ceilings, including light fixtures <strong>and</strong> HVAC equipment.<br />

1. Structural Class: Intermediate-duty.<br />

B. Attachment Devices: Size for 5 times design load indicated in ASTM C635, Table<br />

1 Direct Hung. Hanger Wires-galvanized carbon steel, ASTM A641, soft temper,<br />

prestretched, yield-stress load of at least 3 times design load, but not less than 12<br />

gage (0.106").<br />

C. Edge Molding: provide manufacturer’s st<strong>and</strong>ard wall angle (7/8” hemmed angle<br />

molding) for edges of ceiling of material <strong>and</strong> finish to match exposed tee flanges in<br />

same space unless otherwise noted below.<br />

D. Exposed Suspension System: Manufacturer's st<strong>and</strong>ard exposed tees, cross tees<br />

<strong>and</strong> accessories of types indicated, with exposed cross tees coped to lay flush<br />

with main runners. Hot dipped galvanized steel on all surfaces of ceiling<br />

suspension system, including mouldings, trim <strong>and</strong> accessories.<br />

E. Suspension System:<br />

1. For “ACT1” <strong>and</strong> “ACT2” Ceilings:<br />

a. Prelude XL 15/16” Exposed Tee Grid System by Armstrong.<br />

b. Donn DX 15/16” Exposed Tee Grid System by USG.<br />

c. Classic Stab System 15/16” Exposed Tee Grid System by Certainteed.<br />

PART 3 – EXECUTION<br />

3.1 EXAMINATION<br />

A. Installer must examine conditions under which acoustical ceiling work is to be<br />

performed <strong>and</strong> must notify Contractor in writing of unsatisfactory conditions. Do<br />

not proceed with work until unsatisfactory conditions have been corrected in<br />

manner acceptable to installer.<br />

3.2 PREPARATION<br />

A. Measure each ceiling area <strong>and</strong> establish layout of acoustical units to balance<br />

border widths at opposite edges of each ceiling – in accordance with approved<br />

coordination layout drawing.<br />

MAHG121038 09 51 13 - 3 ACOUSTICAL PANEL CEILINGS