21 CFR 175 Indirect Food Additives: Adhesives <strong>and</strong><br />

Components of Coatings<br />

40 CFR 50.12 National Primary <strong>and</strong> Secondary Ambient Air<br />

Quality St<strong>and</strong>ards for Lead<br />

PL 109-58<br />

Energy Policy Act of 2005 (EPAct05)<br />

UNDERWRITERS LABORATORIES (UL)<br />

UL 174<br />

(2004; Rev thru Apr 2009) Household Electric<br />

Storage Tank Water Heaters<br />

1.2 SUBMITTALS<br />

Government approval is required for submittals with a "G" designation;<br />

submittals not having a "G" designation are for information only. When<br />

used, a designation following the "G" designation identifies the office that<br />

will review the submittal for the Government. The following shall be<br />

submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:<br />

SD-02 Shop Drawings<br />

SD-03 Product Data<br />

Plumbing System; G,<br />

Detail drawings consisting of schedules, performance charts,<br />

instructions, diagrams, <strong>and</strong> other information to illustrate the<br />

requirements <strong>and</strong> operations of systems that are not covered by the<br />

Plumbing Code.. Detail drawings for the complete plumbing system<br />

including piping layouts <strong>and</strong> locations of connections; dimensions<br />

for roughing-in, foundation, <strong>and</strong> support points; schematic diagrams<br />

<strong>and</strong> wiring diagrams or connection <strong>and</strong> interconnection diagrams.<br />

Detail drawings shall indicate clearances required for maintenance<br />

<strong>and</strong> operation. Where piping <strong>and</strong> equipment are to be supported<br />

other than as indicated, details shall include loadings <strong>and</strong><br />

proposed support methods. Mechanical drawing plans, elevations,<br />

views, <strong>and</strong> details, shall be drawn to scale.<br />

Fixtures; (LEED)<br />

List of installed fixtures with manufacturer, model, <strong>and</strong> flow<br />

rate.<br />

Flush valve water closets<br />

Wall hung lavatories<br />

Service sinks<br />

Section 22 00 00 Page 11