conditions of this level.<br />

3. Level 3: Gypsum board substrate at areas of textured finishes <strong>and</strong> heavy duty<br />

wall coverings.<br />

a. All joints <strong>and</strong> interior angles shall have tape embedded in joint compound<br />

<strong>and</strong> one additional coat of joint compound applied over all joints <strong>and</strong><br />

interior angles. Fastener heads <strong>and</strong> accessories shall be covered with<br />

two separate coats of joint compound. All joint compound shall be smooth<br />

<strong>and</strong> free of tool marks <strong>and</strong> ridges.<br />

4. Level 4: all Gypsum board surfaces, except where another finish level is<br />

indicated.<br />

a. All joints <strong>and</strong> interior angles shall have tape embedded in joint compound<br />

<strong>and</strong> two separate coats of joint compound applied over all flat joints <strong>and</strong><br />

one separate coat of joint compound applied over interior angles.<br />

Fastener heads <strong>and</strong> accessories shall be covered with three separate<br />

coats of joint compound. All joint compound shall be smooth <strong>and</strong> free of<br />

tool marks <strong>and</strong> ridges.<br />

5. Level 5: not used on this Project.<br />

3.5 FIELD QUALITY CONTROL<br />

A. Tolerances:<br />

3.6 PROTECTION<br />

1. Do not exceed 1/8 inch in 8'-0" variation from plumb or level in exposed lines<br />

of surface, except at joints between gypsum board units.<br />

2. Do not exceed 1/16 inch variation between planes of abutting edges or ends.<br />

3. Shim as required to comply with specified tolerances.<br />

A. Protect installed products from damage from weather, condensation, direct<br />

sunlight, construction, <strong>and</strong> other causes during remainder of the construction<br />

period.<br />

B. Remove <strong>and</strong> replace panels that are wet, moisture damaged, <strong>and</strong> mold damaged.<br />

1. Indications that panels are wet or moisture damaged include, but are not<br />

limited to, discoloration, sagging, or irregular shape.<br />

2. Indications that panels are mold damaged include, but are not limited to, fuzzy<br />

or splotchy surface contamination <strong>and</strong> discoloration.<br />

END OF SECTION<br />