C. Roofing Manufacturer’s Warranty: Upon completion of the work, furnish to the<br />

Owner the manufacturer’s written <strong>and</strong> signed st<strong>and</strong>ard roofing & metal warranty,<br />

including asphalt, fasteners, wood blocking, rigid/tapered insulation, recovery<br />

board, modified bitumen system, all metal flashings, liquid flashings, duct <strong>and</strong> pipe<br />

supports, metal copings, <strong>and</strong> related accessories, certifying the performance of<br />

his products <strong>and</strong> the consistency of the properties of such products affecting their<br />

performance for the following:<br />

1. 20 year complete roofing system material <strong>and</strong> workmanship no dollar limit<br />

system warranty<br />

a. During roof warranty period, manufacturer’s representative <strong>and</strong> roofing<br />

contractor agree that as soon as practical after receipt of notice from<br />

Owner, they will inspect <strong>and</strong> cause immediate emergency repairs to be<br />

made to defects <strong>and</strong> leaks threatening interior of building.<br />

b. Manufacturer <strong>and</strong> Roofing Contractor further agree to effect permanent<br />

repairs to defects or leaks within 30 days of Owner’s notice without cost<br />

to Owner.<br />

c. The manufacturer shall review the requirements of the plans,<br />

specifications <strong>and</strong> project prior to bidding. Any conditions which may<br />

negatively effect the warranty must be identified in writing prior to bidding.<br />

No exception to warranty is acceptable.<br />

d. Refer to Division 7 Section “Flashing <strong>and</strong> Sheet Metal” for metal flashing<br />

information.<br />

D. Emergency Repairs: Owner reserves prerogative of making immediate<br />

emergency repairs, at their own expense, to conditions threatening building<br />

contents without abrogating their rights under this warranty.<br />

E. Type Repairs: Make permanent restoration using proper laminar reconstruction<br />

with hot bitumen <strong>and</strong> reconstruct to original condition using materials <strong>and</strong> methods<br />

originally manufacturer specified or as outlined by manufacturer’s written<br />

requirements.<br />

1.11 LABORATORY TESTING<br />

A. Upon request from the Architect the membrane manufacturers shall supply, at<br />

their expense, the results of mechanical <strong>and</strong> chemical testing performed on the<br />

asphalt materials supplied.<br />

B. The tests shall be performed to certify compliance with the st<strong>and</strong>ards referenced<br />

under this section.<br />

C. Other tests may be performed upon request. Refer to “Final Inspection”<br />

paragraph.<br />

1.12 SITE PROTECTION<br />

MAGH121038<br />

07 52 16-5 MODIFIED BITUMINOUS MEMBRANE ROOFING