A. During roofing work, exposed surfaces of finished walls shall be protected with<br />

tarps in order to prevent damage. Contractor shall assume full responsibility for<br />

any damage.<br />

PART 2 – PRODUCTS<br />

2.1 MANUFACTURERS<br />

A. Soprema USA<br />

B. Johns Manville<br />

C. Firestone Building Products Co.<br />

D. GAF<br />

2.2 MATERIALS<br />

A. Asphalt:<br />

1. Asphalt shall be certified in full compliance with the requirements of Type<br />

Type IV asphalt listed in Table 1, ASTM D-312-71. Each container, or bulk,<br />

shipping ticket shall indicate the equiviscous temperature (EVT), the finished<br />

blowing temperature (FBT), <strong>and</strong> the flash point.<br />

B. Base Sheet:<br />

1. Sopra-G as manufactured by Soprema or from one of equal manufacturers.<br />

C. .Insulation:<br />

1. Insulation shall be a rigid polyisocyanurate board with facing material<br />

acceptable to the membrane manufacturer for the system specified.<br />

2. Tapered insulation is required at various locations – see roof plan for locations.<br />

3. Insulation adhesive: provide equal to “Olybond Classic” as manufactured by<br />

OMG Roofing Products, <strong>Inc</strong>.<br />

D. Recovery Board:<br />

1. Recovery board to be 1/2 inch thick (unless otherwise noted). Layer to be hot<br />

asphalt applied or attached with insulation adhesive, depending on<br />

manufacturer.<br />

2. Provide products from one of the following:<br />

a. “Sopraboard”; Soprema<br />

MAGH121038<br />

07 52 16-6 MODIFIED BITUMINOUS MEMBRANE ROOFING