material <strong>and</strong> a flush or “tapered” transition, color to match flooring, or as<br />

selected by Architect from manufacturer’s st<strong>and</strong>ard colors. Provide as<br />

follows:<br />

a. VCT to sealed concrete: Johnsonite “RRS-XX-D” (25’ rolls)<br />

b. VCT to carpet: Johnsonite “CTA-XX-A”<br />

c. Provide all other transitions as required to finish any raw edge of resilient<br />

flooring.<br />

C. Adhesives (Cements):<br />

(1) Transitions to tile are as specified in Division 9 Section “Tiling”.<br />

1. Use adhesives that comply with the following limits for VOC content when<br />

calculated according to 40 CFR 59, Subpart D (EPA Method 24):<br />

a. Floor Adhesives: Not more than 60 g/L.<br />

b. Cove Base Adhesives: Not more than 50 g/L. Provide equal to<br />

Armstrong S-725 WallBase Adhesive.<br />

2. Static Dissipative Tile Only:<br />

a. Provide 2 inch wide x 24 inch long copper ground-connection strips under<br />

the tile.<br />

D. Concrete Slab Primer:<br />

1. Low-VOC non-staining type as recommended by flooring manufacturer.<br />

E. Leveling <strong>and</strong> Patching Compounds:<br />

1. Low-VOC latex-type as recommended by manufacturer of resilient products.<br />

PART 3 – EXECUTION<br />

3.1 EXAMINATION<br />

A. Installer must examine sub-floor surfaces to determine that they are satisfactory.<br />

A satisfactory sub-floor surface is defined as one that is smooth <strong>and</strong> free from<br />

cracks, holes, ridges, <strong>and</strong> coatings preventing adhesive bond, <strong>and</strong> other defects<br />

impairing performance or appearance.<br />

B. Perform subfloor moisture testing in accordance with ASTM F 1869,“St<strong>and</strong>ard Test<br />

Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using<br />

Anhydrous Calcium Chloride” <strong>and</strong> Bond Tests as described in publication F-5061,<br />

"Armstrong Guaranteed Installation System," to determine if surfaces are dry; free<br />

of curing <strong>and</strong> hardening compounds <strong>and</strong> other coatings; <strong>and</strong> ready to receive<br />

MAHG121038 09 65 19 - 4 RESILIENT TILE FLOORING