3.11 CLEANING<br />

E. If core cuts verify the presence of damp or wet materials, the Contractor shall be<br />

required to replace the damaged areas at his own expense.<br />

F. Repair or replace deteriorated or defective work found at time above inspection as<br />

required to a produce an installation which is free of damage <strong>and</strong> deterioration at<br />

time of Substantial Completion <strong>and</strong> according to warranty requirements.<br />

G. Notify the Architect upon completion of corrections.<br />

H. Following the final inspection, provide written notice of acceptance of the<br />

installation from the roofing system manufacturer.<br />

I. Immediately correct roof leakage during construction. If the Contractor does not<br />

respond within twenty four (24) hours, the Owner will exercise rights to correct the<br />

Work under the terms of the Conditions of the Contract.<br />

A. Clean-up <strong>and</strong> remove daily from the site all wrappings, empty containers, paper,<br />

loose particles <strong>and</strong> other debris resulting from these operations.<br />

B. Remove asphalt markings from finished surfaces.<br />

C. Repair or replace defaced or disfigured finishes caused by work of this section.<br />

3.12 DEMONSTRATION AND TRAINING<br />

A. At a time <strong>and</strong> date agreed to by the Owner, instruct the Owner's representative on<br />

the following procedures:<br />

3.13 PROTECTION<br />

1. Roof troubleshooting procedures.<br />

2. Notification procedures for reporting leaks or other apparent roofing problems.<br />

3. Roofing maintenance.<br />

4. The Owner's obligations for maintaining the roofing warranty in effect <strong>and</strong><br />

force.<br />

5. The Manufacturer's obligations for maintaining the roofing warranty in effect<br />

<strong>and</strong> force.<br />

A. Provide traffic ways, erect barriers, fences, guards, rails, enclosures, chutes <strong>and</strong><br />

the like to protect personnel, roofs <strong>and</strong> structures, vehicles <strong>and</strong> utilities.<br />

B. Special permission must be obtained from the Manufacturer before any traffic will<br />

be permitted over new roofing.<br />

END OF SECTION<br />

MAGH121038<br />

07 52 16-14 MODIFIED BITUMINOUS MEMBRANE ROOFING