2.3 ACCESSORIES<br />

A. Miscellaneous Materials:<br />

1. Cleaners, Primers <strong>and</strong> Sealers: Type recommended by sealant or gasket<br />

manufacturer.<br />

2. Setting Blocks: Neoprene or EPDM, 79-90 durometer hardness, with proven<br />

compatibility with sealants used.<br />

3. Spacers: Neoprene or EPDM, 40-50 durometer hardness with proven<br />

compatibility with sealants used.<br />

4. Compressible Filler (Rod): Closed-cell or waterproof-jacketed rod stock of<br />

synthetic rubber or plastic foam, proven to be compatible with sealants used;<br />

flexible <strong>and</strong> resilient, with 5-10 psi compressive strength for 25% deflection.<br />

B. Structural Sealant<br />

1. Structural Sealant: ASTM C 1184, chemically curing silicone formulation that<br />

is compatible with system components with which it comes in contact,<br />

specifically formulated <strong>and</strong> tested for use as structural sealant.<br />

a. Provide sealants for use inside that have a VOC content of 100 g/L or<br />

less when calculated according to 40 CFR 59, Subpart D (EPA<br />

Method 24).<br />

b. Color: Black.<br />

PART 3 – EXECUTION<br />

3.1 PREPARATION<br />

A. Clean glazing channel <strong>and</strong> other framing members to receive glass, immediately<br />

before glazing. Remove coatings which are not firmly bonded to substrate.<br />

Remove lacquer from metal surfaces where elastomeric sealants are used.<br />

B. Apply primer or sealant to joint surfaces where recommended by sealant<br />

manufacturer.<br />

3.2 INSTALLATION<br />

A. General:<br />

1. Watertight <strong>and</strong> airtight installation of each glass product is required, except as<br />

otherwise shown. Each installation must withst<strong>and</strong> normal temperature<br />

changes, wind loading, <strong>and</strong> impact loading (for doors), without failure,<br />

including loss or breakage of glass, failure of sealants to remain watertight<br />

<strong>and</strong> airtight, deterioration of glazing materials <strong>and</strong> other defects in the work.<br />

MAHG121038 08 80 00 - 3 GLAZING