e. Install supplementary framing, runners, blocking <strong>and</strong> bracing at openings<br />

<strong>and</strong> terminations in the work, <strong>and</strong> at locations required to support fixtures,<br />

equipment, services, heavy trim <strong>and</strong> similar work which cannot be<br />

adequately supported on gypsum board alone.<br />

f. Secure perimeter framing to structural elements with suitable fasteners<br />

located 2 inches from each end <strong>and</strong> 24 inches apart between, except top<br />

runner parallel to, but not directly under, framing members will be<br />

attached with 2 screws to headers provided at 48 inches on center.<br />

Anchor studs adjacent to door <strong>and</strong> fixed light openings, partition<br />

intersections, <strong>and</strong> corners to top <strong>and</strong> bottom runner flanges. Make webflange<br />

bend at each end of runner over openings <strong>and</strong> screw to jamb studs<br />

with 2 screws each end.<br />

3. Slip-Type Head Joints: Where framing extends to overhead structural<br />

supports, install to produce joints at tops of framing systems that prevent axial<br />

loading of finished assemblies.<br />

END OF SECTION<br />

MAHG121038 09 22 16 - 5 NON-STRUCTURAL METAL FRAMING