Threaded Ends<br />

Backwater Valves<br />

ASME A112.14.1<br />

Vacuum Relief Valves CSA/AM Z21.22<br />

Water Pressure Reducing Valves ASSE 1003<br />

Water Heater Drain Valves ASSE 1005<br />

Trap Seal Primer Valves ASSE 1018<br />

Temperature <strong>and</strong> Pressure Relief Valves CSA/AM Z21.22<br />

for Hot Water Supply Systems<br />

Temperature <strong>and</strong> Pressure Relief Valves<br />

for Automatically Fired Hot<br />

Water Boilers<br />

ASME CSD-1<br />

Safety Code No., Part CW,<br />

Article 5<br />

2.3.1 Wall Faucets<br />

Wall faucets with vacuum-breaker backflow preventer shall be brass with 3/4<br />

inch male inlet threads, hexagon shoulder, <strong>and</strong> 3/4 inch hose connection.<br />

Faucet h<strong>and</strong>le shall be securely attached to stem.<br />

2.3.2 Relief Valves<br />

Water heaters <strong>and</strong> hot water storage tanks shall have a combination pressure<br />

<strong>and</strong> temperature (P&T) relief valve. The pressure relief element of a P&T<br />

relief valve shall have adequate capacity to prevent excessive pressure<br />

buildup in the system when the system is operating at the maximum rate of<br />

heat input. The temperature element of a P&T relief valve shall have a<br />

relieving capacity which is at least equal to the total input of the heaters<br />

when operating at their maximum capacity. Relief valves shall be rated<br />

according to CSA/AM Z21.22. Relief valves for systems where the maximum<br />

rate of heat input is less than 200,000 Btuh shall have 3/4 inch minimum<br />

inlets, <strong>and</strong> 3/4 inch outlets. Relief valves for systems where the maximum<br />

rate of heat input is greater than 200,000 Btuh shall have 1 inch minimum<br />

inlets, <strong>and</strong> 1 inch outlets. The discharge pipe from the relief valve shall<br />

be the size of the valve outlet.<br />

2.3.3 Thermostatic Mixing Valves<br />

Provide thermostatic mixing valve for lavatory faucets. Mixing valves,<br />

thermostatic type, pressure-balanced or combination thermostatic <strong>and</strong><br />

pressure-balanced shall be line size <strong>and</strong> shall be constructed with rough or<br />

finish bodies either with or without plating. Each valve shall be<br />

constructed to control the mixing of hot <strong>and</strong> cold water <strong>and</strong> to deliver water<br />

at a desired temperature regardless of pressure or input temperature<br />

changes. The control element shall be of an approved type. The body shall<br />

be of heavy cast bronze, <strong>and</strong> interior parts shall be brass, bronze,<br />

corrosion-resisting steel or copper. The valve shall be equipped with<br />

necessary stops, check valves, unions, <strong>and</strong> sediment strainers on the inlets.<br />

Mixing valves shall maintain water temperature within 5 degrees F of any<br />

setting.<br />