11.07.2015 Views

Operating Manual Vol 1 - ES Documentation

Operating Manual Vol 1 - ES Documentation

Operating Manual Vol 1 - ES Documentation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

External Modulation Source AMIQSMIQ(SELECTWAVEFORM/EXECUTE BATCH...)WAVEFORM...SET SMIQ LEVELACCORDING TOWAVEFORMEXECUTE BATCHFROM FLOPPYFILE INFOSelects the signal data to be loaded. The dataavailable on diskette or hard disk are offered in aselect window. After selecting the signal data, thefollowing actions are performed:1. stopping the currently active signal output,2. preparing the selected signal data,3. further procedure is according to parameterMODE in main menu.Waveform files may contain information on LEVELOFFSET and CR<strong>ES</strong>T FACTOR. If this function isactive, these values are set automatically uponloading the waveform. If no waveform is loaded, theyare set to zero.Executes the batch file WINIQSIM.IEC generated byWinIQSIM from diskette. The signal data includingthe given directory structure are stored on the AMIQhard disk.The directory structure is defined by the user duringthe generation of the diskette.All menu entries displayed under FILE INFO are noteditable. The file info (date, comment and origin aswell as power offset of modulation) from the selectedfiles is displayed.MODEConfiguration of trigger conditions for signal output. Any change in the triggerconditions resets the signal output and starts it again. Retriggering a runningsignal output is inhibited.OFFAUTOSINGLEGATEDEXT-AUTOEXT-SINGL<strong>ES</strong>tops the signal output, output of the idle signal.Continuous signal output, trigger events are ignored.Prepares a single signal output. The idle signal is outputfirst. Signal output is started via menu item EXECUT<strong>ES</strong>INGLE . After completion of the signal output, the idlesignal is output. External trigger events are ignored.The level of the signal applied to the trigger input controlsthe output.If the level (HIGH/LOW) set under EXT TRIG SLOPE isapplied, the signal output will be restarted and the signalwill be output continuously. If the level set under EXTTRIG SLOPE is not applied, the output will be interruptedand the idle signal will be output.Continuous signal output. The idle signal is output first.The signal output is started via an external trigger event.Further trigger events are ignored. A signal slope whosepolarity is configured in menu item EXT TRIG SLOPE(POS/NEG) is taken as a trigger event.Prepares a single signal output. The idle signal is outputfirst. The signal output is started via an external triggerevent. After completion of the signal output, the idlesignal is output until the next trigger event is obtained.1125.5555.03 2.362 E-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!