11.07.2015 Views

Operating Manual Vol 1 - ES Documentation

Operating Manual Vol 1 - ES Documentation

Operating Manual Vol 1 - ES Documentation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Bit Error Rate TestSMIQSTATEMODEEXECUTE SINGLEThe status information described in the following tells the user whether theBER measurement is working. The STATE display signals the status of clockline, data line and synchronization. If the clock signal changes, CLOCK isindicated as status, otherwise NO CLOCK. The same applies to the datadisplay DATA or NO DATA. NO DATA may be displayed because DATAENABLE is not set to NOT USED or the data enable signal does not enablethe data. SYNC indicates a successful attempt of PRBS synchronization bythe analyzer. It is not before all three of CLOCK, DATA and SYNC are "active"that the measurement results are valid.CLOCKChange of clock signal.NO CLOCK No change of clock signal.DATAChange of data signal.NO DATA No change of data signal.SYNCSuccessful synchronization to PRBS.NO SYNC No synchronization.The seven parameters listed above (data bits, error bits, error rate, attribute"terminated", attribute CLOCK, attribute DATA, attribute SYNC) are jointlypolled by the IEC/IEEE bus query :BERT:R<strong>ES</strong>? .Setting for the BER measurement.OFF Terminate measurement.AUTO Continuous measurement of bit error rate. If one or both criteria fortermination are fulfilled, a new measurement is initiatedautomatically. Depending on the settings made, a measurementmay take considerable time. During the first measurement,intermediate results are displayed. For the measurements thatfollow, only the final results are shown. The parameters DATA BITSand ERRORS are continuously updated and indicate the relativevalues for the measurement in progress.SINGLE Single measurement of bit error rate. During the measurement, theSMIQ cyclically displays the updated values for rate, number oferrors and number of data bits. If any one of the termination criteria(TERMINATION ATTRIBUT<strong>ES</strong> [DATA BITS] and TERMINATIONATTRIBUT<strong>ES</strong> [ERRORS]) is reached, the measurement is stopped.A single measurement is initiated only if the menu item EXECUT<strong>ES</strong>INGLE is selected.IEC/IEEE-bus command :BERT:STAT ON:BERT:SEQ SINGInitiates a single BER measurement. This menu item is only displayed ifMODE = SINGLE is set.IEC/IEEE-bus command :TRIG:BERT:IMMTERMINATIONATTRIBUT<strong>ES</strong>DATA BITSERRORSSetting the termination criterion "Number of transmitted data bits".IEC/IEEE-bus command :BERT:SET:MCO Setting the termination criterion "Maximum number of detectederrors".IEC/IEEE-bus command :BERT:SET:MERR 1125.5555.03 2.370 E-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!