29.07.2013 Views

particular specifications (road works) - CIDCO Maharashtra Ltd.

particular specifications (road works) - CIDCO Maharashtra Ltd.

particular specifications (road works) - CIDCO Maharashtra Ltd.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CIDCO</strong> OF MAHARASHTRA LTD<br />

C.A.No.01/<strong>CIDCO</strong>/SE(KHR)/EE(KHR-I)/2010–11 Pg. No. 417<br />

shall be placed on the panel and the vacuum pick up nozzle kept in<br />

position. The counter shall be set in position. The vacuum, pick up and<br />

turn table of the abrader shall be fixed for 1000 cycles. After 1000<br />

cycles loose abradings remaining on the test specimen shall be<br />

measured for finding the loss in weight. The weight loss shall not<br />

exceed 100mg. The test shall be conducted on duplicate specimens.<br />

14.10.4 Test Procedure D:<br />

Chloride Tolerable Limit:<br />

10mm dia. cement polymer coated rod of length 10cm shall be used.<br />

Bottom edge of the coated rod shall be sealed using lacquer. Then test<br />

specimen is kept immersed in 0.04 N NaOH + 10,000 ppm chloride<br />

and potential is monitored using high impedance Multimeter against<br />

suitable reference electrode such as saturated calomel electrode. After<br />

getting stabilized potential, using appropriate current regulator (0-<br />

100mA), the test specimen is anodically polarized at a constant current<br />

density of 290 uA/cm2 using a platinum/stainless steel/TSIA/Polished<br />

mild steel as cathode. Potential with time is followed for 5 minutes. At<br />

the end of 5 minutes, no rust spots shall be observed on the coated<br />

rod.<br />

14.10.5 Test Procedure E:<br />

Chemical Resistance of the Coating:<br />

The coated rods (any diameter) of length 30cm shall be used in this<br />

test. The bottom edge of the coated rods are to be sealed using<br />

lacquer. Transparent PVC cylindrical container shall be used. 3M<br />

CaC123M NaOH, Saturated Ca (OH) 2 and distilled water are prepared<br />

as individual test solution and filled in the separate container up to the<br />

half of its height. Then the coated rods are kept partially immersed in<br />

the test solution so that they are in long term contact with both the<br />

liquid and vapor phase of the test solution. The test shall be conducted<br />

for 45 days. The coating should not blister, soften or disband during<br />

this period.