<strong>CIDCO</strong> OF MAHARASHTRA LTD<br />

C.A.No.01/<strong>CIDCO</strong>/SE(KHR)/EE(KHR-I)/2010–11 Pg. No. 429<br />

Precast panels shall be cast to the required design with specified<br />

reinforcement and temped and cured for 14 days. They shall originally<br />

present smooth surfaces and shall be filled into the grooves left into the<br />

kerb properly supported and grouted. Thereafter the R.C.C. post and<br />

rail will be cast. Precast top rails may also be used along with precast<br />

panels in which case only posts will be cast in situ. The cast-in-situ<br />

members shall be plastered with 1:3 cement mortar 6mm (about ¼”)<br />

thick to smooth or sand face finish, immediately after and within one<br />

day of stripping the forms after roughening and cured for 14 days.<br />

19.4 Item to include:<br />

1) Providing R.C.C. cast-in-situ M-35 grade posts cast-in-<br />

situ/precast concrete panels and cast-in-situ/precast rails as<br />

shown in the drawing including form work and 6mm (about ¼”)<br />

thick plaster of cement mortar of 1:3 mix for cast-in-situ<br />

members.<br />

2) Reinforcement for precast and cast-in-situ members.<br />

3) All labour, materials, use of equipment, tools, plant, scaffolding<br />

etc. necessary for the completion of the item satisfactorily. No<br />

separate payment shall be made for concrete and reinforcement<br />

of R.C.C. members, the rate per metre being inclusive of all the<br />

necessary materials like those mentioned above.<br />

19.5 Mode of measurement and payment:<br />

The contract rate shall be for one metre length of the parapet<br />

completed to the shape and dimension shown on the drawings. The<br />

parapet shall be measured between the inside of the end pilasters over<br />

the abutments. Where there are only end posts, the parapet shall be<br />

measured from outside to outside of end posts. The length shall be<br />

measured correct upto two places of decimals of a metre.