<strong>CIDCO</strong> OF MAHARASHTRA LTD<br />

C.A.No.01/<strong>CIDCO</strong>/SE(KHR)/EE(KHR-I)/2010–11 Pg. No. 544<br />

Where required suitable expansion joints shall also be provided as<br />

directed by the Engineer.<br />

The time of day selected for concreting shall also be chosen so as to<br />

minimize placing temperatures. In case of concreting in exceptionally<br />

hot weather the Engineer may in his discretion specify the use of ice<br />

either flaked and used directly in the mix or blocks used for chilling<br />

the mixing water. In either case the cost of ice either flaked and used<br />

directly in the mix or blocks used for chilling the mixing water. In<br />

either case the cost of ice and additional labor involved in weighing<br />

and mixing etc. shall be borne by the contractor and noting will be<br />

paid on this account.<br />

1.5 Defective Concrete :<br />

Should any concrete be found honeycombed or in any way defective,<br />

such concrete shall on the instruction of the Engineer be cut out by<br />

the Contractor and made good at his own expenses.<br />

1.6 Exposed Faces, Holes and Fixtures :<br />

On no account shall concrete surfaces be patched or covered up or<br />

damaged concrete rectified or replaced until the Engineer or his<br />

representative has inspected the <strong>works</strong> and issued written instructions<br />

for rectification. Failure to observe this procedure will render that<br />

portion of the <strong>works</strong> liable to rejection; in which case it will be<br />

treated as a work which has failed to meet specified strength<br />

requirements and dealt with according to Clause 1.11.<br />

Holes for foundation or other bolts or for any other purposes shall<br />

be moulded, and steel angles, holdfasts or other fixtures shall be<br />

embedded, according to the drawings or as instructed by the<br />

Engineer.