14.12.2012 Views

SPME Applications Guide - Overbrook Scientific

SPME Applications Guide - Overbrook Scientific

SPME Applications Guide - Overbrook Scientific

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

(New references added to the 7th edition are in bold) <strong>SPME</strong> Fiber /<br />

Analyte / Extraction<br />

Matrix Literature Reference Conditions Instrument<br />

2269 TNT in sand explosives buried in sand Immersion GC-ECD<br />

Proc SPIE Int Soc Opt Eng (2005) 5794 #II, 1272-1280 GC/MS<br />

Baez, B.; Briano, J.; Castro, M..; Correa, S.; De Echevarria, M.<br />

Hernandez-Rivera, S.<br />

2270 TNT in sand<br />

Transport of explosives II: Use of Headspace-<strong>SPME</strong>/GC-ECD and<br />

TEEM GC/MS for detection of TNT vapors from sand buried samples Headspace GC-ECD<br />

Proc SPIE Int Soc Opt Eng (2005) 5794 #II, 1263-1271<br />

Baez, B.; Briano, J.; Castro, M..; Correa, S.; De Echevarria, M.<br />

Hernandez-Rivera, S.<br />

GC/MS<br />

<strong>SPME</strong> sampling of high explosive resideus in the presence<br />

2383 Explosive residue of radionuclides and radioneclide surrogate metals<br />

J Radioanalytical and Nuclear Chemistry -2007-04-13<br />

Duff, M., Crump, S., Robert, R., Beals, D.<br />

Bioconcentration factor hydrophobicity cutoff: An artificial<br />

2675 PAHs in phenomenon reconstructed<br />

aquatic worm ENVIRON. SCI. TECHNOL. 41, #21, 7363-7369 (01 NOV 2007)<br />

Jonker, M. T. O.; Van, Der Heijden S. A.<br />

668 TNT, 2,4-DNT, RDX<br />

Development of field screening methods for TNT, 2,4-DNT,<br />

and RDX in soil.<br />

in soil Talanta, 39: 419-28 (1992)<br />

T Jenkens, et al<br />

812 RDX, HMX<br />

Detection of the cyclic nitramine explosives hexahydro<br />

1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7- 65µm PDMS/DVB GC-MS<br />

in soil tetranitro-1,3,5,7-tetrazine (HMX) and their degradation 20MIN @55°c LC-MS<br />

products in soil environments<br />

J Chromatog A (2001) 909(1), 53-60<br />

Hawari, J; Beaudet, S; Groom, C.; Halasz, A; Paquet, L<br />

PFBHA derivative<br />

344 explosives<br />

Trace Analysis of explosives in Seawater Using <strong>SPME</strong> and<br />

GC-Ion Trap Mass Spectrometry 65µm Carbowax/DVB GC-MS<br />

in salt water Anal. Chem., Vol. 70, No. 14, July 15, 1998, pg. 3015-3020 60 min<br />

Barshick, S., Griest, W. immersion<br />

stirring<br />

Solid-phase microextraction coupled to GCfor the determination<br />

2394 2,3-dimethyl-2,3- of 2,3-dimethyl-2,3-dinitrobutane as a marking agent for explosives headspace GC<br />

dinitrobutane Talanta 72, #4, 1581-1585 (2007-06-15) 30 sec @ 22°C<br />

from ammonium<br />

nitrate<br />

Li, X. J.; Zeng, Z. R.; Zeng, Y.<br />

Application of a <strong>SPME</strong>-IMS detection system for explosives detection<br />

2284 Explosives Proc SPIE Int Soc Opt Eng Vol 5778 #2, 667-672 (2005) headspace GC/IMS<br />

in open areas. Almirall, Jose R.; Furton, Kenneth G.; Perr, Jeannette M.<br />

Discrimination of smokeless powders by headspace <strong>SPME</strong>-GC-MS<br />

2285 Odors from and <strong>SPME</strong>-GC-ECD, and the potential implications upon training headspace GC-MS<br />

smokeless canine detection of explosives GC-ECD<br />

powders Proc SPIE Int Soc Opt Eng Vol 5778 #2, 638-643 (2005)<br />

Almirall, Jose R.; Furton, Kenneth G.; Harper, Ross J.<br />

2370 Explosives<br />

<strong>SPME</strong>-HPLC: A new approach to the analysis of explosives<br />

J. HAZARD. MATER. 14, # 3, 691-697 (2007)<br />

Gaurav; Kaur, V.; Kumar, A.; Malik, A. K.; Rai, P. K.<br />

65µm CW/DVB HPLC<br />

669 Explosives<br />

Application of <strong>SPME</strong> to the recovery of explosives and<br />

ignitable liquid residues from forensic specimens 65µm Carbowax/DVB GC-ECD<br />

from solids, water J. Chromatogr A, 885(2000) 419-432 25 min, 25% NaCl HPLC<br />

Furton, K., Almirall, J., Bi, M., Wang, J., Wu, L. immersion<br />

stirring<br />

592 explosives<br />

An improved interface for coupling <strong>SPME</strong> to HPLC<br />

applied to the analysis of explosives 50µm Carbowax/TPR HPLC-UV<br />

Ambient temperature, unless otherwise indicated. 129

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!