(New references added to the 7th edition are in bold) <strong>SPME</strong> Fiber /<br />
Analyte / Extraction<br />
Matrix Literature Reference Conditions Instrument<br />
2844 Organics organic micropollutants from aqueous samples and analysis by GC-MS DVB/Cab (30/50 μm) GC-MS<br />
in water Anal. Chim. Acta 618, #1, 61-69 (Jun 16 2008)<br />
Gupta, Manju; Jain, Archana; Pillai, Aradhana K.K.V.; Verma, K.<br />
Target and nontarget screening of organic micropollutants in water by<br />
2339 Organics <strong>SPME</strong>s combined with GC-TOF-MS<br />
in water Anal Chem Vol. 79, # 24 9494-504 (2007 Dec 15) GC-TOF-MS<br />
Hernandez, F.; Portoloes, Tania; Pitarch, Elena; Loopez, F.<br />
2846 PAHs in<br />
<strong>SPME</strong> followed by HPLC with fluorimetric and UV detection for<br />
the determination of polycyclic aromatic hydrocarbons in water 65µm PDMS/DVB LC-UV<br />
water Analytical Letters 41, #1, 119-136 (2008) 60 min @ 70°C<br />
Ricardo Lucio-Gutierrez, J.; de la Luz Salazar-Cavazos, Maria;<br />
Waksman de Torres,Noemi H.; Castro-Rios, Rocio<br />
immersion<br />
2397 PAHs in<br />
Determination of PAHs in aqueous samples by microwave assisted<br />
headspace <strong>SPME</strong>-GC-FID 65µm PDMS/DVB GC-FID<br />
water Talanta 72, #4, 1269-1274 (2007-06-15)<br />
Wei, M. -C.; Jen, J. -F.<br />
30 min @ 20°C<br />
<strong>SPME</strong>-GC-MS analysis of PAHs Towards the European<br />
2345 PAHs in Union water directive 2006/0129 EC 65µm PDMS/DVB GC-MS<br />
water J Chromatogr A 1176, #1-2 , 48-56 (2007 Dec 28) immersion GC-MS-MS<br />
Fernoandez-Gonzoalez, V; Concha-Graona, E; Muniategui-Lorenzo, S;<br />
Loopez-Mahoa, P; Prada-Rodroguez, D<br />
Predicting PAH bioaccumulation and toxicity in earthworms exposed to<br />
2543 PAHs in manufactured gas plant soils with solid-phase microextraction<br />
earthworms Env Science & Tech 41, #21, 7472-7478 (NOV 1 2007)<br />
Jonker, T. O.; van der Heijden, S.; Kreitinger, J.; Hawthorne,S.<br />
2596 Organics<br />
Characterization of an urban landfill soil by using physicochemical .<br />
analysis and solid phase microextraction (<strong>SPME</strong>)-GC/MS 65µm PDMS/DVB GC-MS<br />
from soil Env. Monitoring Assessment 127, #1-3, 337-351 (APR 2007) headspace<br />
Banar, Mufide; Ozkan, Aysun; Vardar, Cigdem 15 min @ 50°C<br />
<strong>SPME</strong> to predict bioavailability and accumulation of organic<br />
1947 Organics micropollutants in terrestrial organisms after exposure 30µm PDMS GC-MS<br />
from soil to a field-contaminated soil headspace<br />
Environ. Sci. Technol., 38, #18, 4842-4848 10 days exposure<br />
Barendregt, A; Fleuren, R; Hermens, J.; Jager, T; Sinnige, T.;<br />
Van Der Wal, Leon; Van Gestel, Cornelis A. M.<br />
<strong>SPME</strong> coupled to GC-MS for determining PAH-micelle<br />
1948 PAHs in micelle partition coefficients 85µm polyacrylate GC-MS<br />
micelles Anal. Chem., 76, #15, 4572-4578 100µm PDMS<br />
Alfonso, Ana M.; Ayala, Juan H.; Gonzalez, V; Pino, V.<br />
Implementation of new methods to characterise<br />
1949 Odors from atmospheres in piggeries headspace GC-MS<br />
pig sheds Int. J. Environ. Anal. Chem., 84, #9, 647-659<br />
Begnaud, F.; Berdague, Jean-Louis; Lebost, J.;<br />
Murat, C.; Peres, C.<br />
In-tube solid-phase microextraction and online<br />
1950 Organics in coupling with high-resolution GC. 5 M X 0.53mm ID GC<br />
water LC-GC Europe, 17, #3, 144-151 1.2µm PDMS<br />
Wang, H. W.; Liu, W. M.; Guan, Y. F.<br />
Characterization of volatile organic compounds on<br />
1951 Odor from airborne dust in a swine finishing barn 75µm Carboxen GC<br />
swine Trans. Am. Soc. Agric. Eng., 47, #4, 1231-1238 100µm PDMS<br />
facilities Jeon, I.J.; Maghirang, R.G.; Razote, E.B.; Seitz, L.M headspace<br />
Water<br />
778 Volatile organics<br />
Solid Phase Microextraction of volatile organic compounds<br />
in environmental applications 100µm PDMS GC<br />
in environmental Am Laboratory (2001)33(4), 18-20 85µm Polyacrylate<br />
samples Van Longenhove, H; Dewulf, J. 15 min.<br />
858 Organic pollutants<br />
<strong>SPME</strong> - a convenient tool for the determination of organic<br />
pollutants in environmental matrices<br />
Ambient temperature, unless otherwise indicated. 140