992<br />

DSVG1<br />

Creates pseudo loads or scalar terms required in sensitivity analysis<br />

Parameters:<br />

NOK4GG Input-integer-default=-1. Structural damping generation flag.<br />

-1 Do not generate<br />

0 Generate<br />

WTMASS Input-real-default=1.0. Specifies scale factor on structural mass<br />

matrix.<br />

IAPP Input-integer-default=1. Analysis type. Allowable values are:<br />

1 Statics, aerostatic, frequency, or transient response<br />

2 Buckling or normal modes<br />

4 Flutter or divergence<br />

DSVGF Input-integer-default=0. Specifies scaling of solution vector by<br />

eigenvalue.<br />

0 No scaling<br />

1Scale<br />

NOPSLG Input-integer-default=0. Pseudo-load generation flag. Set to -1 if no<br />

load generation is requested for the current superelement based on<br />

the SEDV Case Control command.<br />

Remarks:<br />

1. DSVG1 must be executed for mass, stiffness, viscous damping, and structural<br />

damping and, if CDIF='YES', forward and backward perturbed configurations.<br />

2. For transient analysis, DSVG1 must be invoked three times for displacement,<br />

velocity, and acceleration which are obtained from the DSAR module.<br />

3. If NOPSLG ≠<br />

0 , then a null EGX matrix is generated.