IFP1 Reads Case Control Section<br />

Reads the Case Control Section.<br />

Format:<br />

Output Data Blocks:<br />

Parameter:<br />

IFP1<br />

Reads Case Control Section<br />

IFP1 /CASECC,PCDB,XYCDB,POSTCDB,FORCE/S,N,NOGOIFP1/<br />

S,N,LASTCC/S,N,BEGSUP $<br />

CASECC Table of Case Control command images.<br />

PCDB Table of model (undeformed and deformed) plotting commands.<br />

XYCDB Table of x-y plotting commands.<br />

POSTCDB Table of commands from the OUTPUT(POST) section of Case Control.<br />

FORCE Table of MSGSTRESS plotting commands defined under the<br />

OUTPUT(CARDS) section in CASE CONTROL and MSGMESH field<br />

information.<br />

NOGOIFP1 Logical-output-default=FALSE. Set to TRUE if an error is detected in<br />

the Case Control Section.<br />

LASTCC Integer-output-default=0. Set to 2 if the last auxiliary model Case<br />

Control section is being processed.<br />

BEGSUP Logical-output-default=FALSE. BEGIN SUPER flag. Set to TRUE if the<br />

first Bulk Data section begins with BEGIN SUPER instead of BEGIN<br />

BULK.<br />

Remarks:<br />

1. IFP1 does not stop if an error is detected in the Case Control section; therefore, the<br />

following statement should appear after the module:<br />

IF (NOGOIFP1) EXIT $<br />

2. IFP1 may be executed only once and should appear at the beginning of the <strong>DMAP</strong><br />

sequence before any other module.<br />