3. ETT may be purged if there are no thermal loads<br />

GP3<br />

Processes static and thermal loads<br />

4. If UGH is present in structural analysis run, then GP3 will create a new<br />

temperature set based on UGH with set identification numbers obtained from<br />

TSTRUC command in CASEHEAT. BGPDTH is used to correlate UGH to grid<br />

points. For h-elements ESTH is not required. For p-elements ESTH is appended<br />

to element ETT record for interpolation purposes in element decks. Here are the<br />

DBVIEW statements that are used to define these inputs in SOLs 101-200:<br />

DBVIEW UGH=UG<br />

DBVIEW ESTH=EST<br />

DBVIEW BGPDTH=BGPDTS<br />

(WHERE APRCH='HEAT ' AND WILDCARD) $<br />

(WHERE APRCH='HEAT ' ) $<br />

(WHERE APRCH='HEAT ') $<br />

CASEHEAT can come from the CASE module or DBLOCATE DATABLK=<br />

(CASECCR/CASEHEAT) in the FMS.<br />

105