1429<br />

STDCON<br />

Calculate stress discontinuities across elements and grid points<br />

STDCON Calculate stress discontinuities across elements and grid points<br />

Calculate stress discontinuities across elements and grid points.<br />

Format:<br />

STDCON CASECC,EGPSF,EQEXIN,OES1,EGPSTR,ECT/<br />

OEDS1,OGDS1,ELDCT,GPDCT/<br />

S,N,NOEDS1/S,N,NOGDS1/S,N,NOELDCT/S,N,NOGDCT/APP $<br />

Input Data Blocks:<br />

CASECC Table of Case Control command images.<br />

EGPSF Table of element to grid point interpolation factors.<br />

EQEXIN Equivalence table between external and internal grid/scalar<br />

identification numbers.<br />

GPL External grid/scalar point identification number list.<br />

OES1 Table of element stresses or strains in SORT1 format.<br />

EGPSTR Table of grid point stresses or strains for post-processing in the DBC<br />

module.<br />

ECT Element connectivity table.<br />

Output Data Blocks:<br />

OEDS1 Table of element stress discontinuities.<br />

OGDS1 Table of grid point stress discontinuities.<br />

ELDCT Table of element stress discontinuities for post-processing in the DBC<br />

module.<br />

GPDCT Table of grid point stress discontinuities for post-processing in the DBC<br />

module.<br />

Parameters:<br />

NOEDS1 Output-integer-default=-1. OEDS1 generation flag. Set to 0 if OEDS1 is<br />

generated.<br />

NOGDS1 Output-integer-default=-1. OGDS1 generation flag. Set to 0 if OGDS1<br />

is generated.<br />

NOELDCT Output-integer-default=-1. ELDCT generation flag. Set to 0 if ELDCT<br />