Parameters<br />

4. Value from the NAME=v, if present in a non-NDDL parameter TYPE<br />

instruction. This value is determined at <strong>DMAP</strong> compile time from the TYPE<br />

instruction (regardless of its location in <strong>DMAP</strong>) that contains the statement.<br />

5. Default value from the NDDL, if the NDDL keyword is specified on the<br />

TYPE <strong>DMAP</strong> statement. Parameters listed in the NDDL always have a<br />

default value of zero, blank, or FALSE, unless a value is explicitly given in<br />

the PARAM NDDL statement.<br />

6. Default value from the first occurrence of either a non-NDDL TYPE <strong>DMAP</strong><br />

statement or a module with a MPL default value. Non-NDDL TYPE <strong>DMAP</strong><br />

statements have a default value of zero, blank, or FALSE for real or integer,<br />

character, or logical parameters.<br />

7. Default value is zero, blank, or FALSE for real or integer, character, or logical<br />

parameters.<br />

Determining the current value of a variable parameter is also summarized in the<br />

following table.<br />

NDDL TYPEd Not TYPEd<br />

Last executed assignment statement or module save (S,N,). The qualifier values for<br />

NDDL parameters cannot change.<br />

Bulk Data PARAM entry override, if parameter is type Y and has not been<br />

previously reassigned in an assignment (=) statement (unless the PVT module has<br />

been executed to reset the Bulk Data and Case Control PARAM entries).<br />

Value on the data base name=v<br />

from its first occurrence in<br />

a TYPE statement<br />

NDDL default value TYPE statement default<br />

Predefined Variable Parameters<br />

MPL default of<br />

parameter first<br />

occurrence<br />

The program predefines the value of some variable parameters. It is not necessary to<br />

type these parameters with a TYPE <strong>DMAP</strong> statement, nor is it possible to change their<br />

type. We do not recommend changing these parameter values. The predefined<br />

variable parameters are:<br />

NAME VALUE TYPE<br />

ALWAYS -1 Integer<br />

NEVER +1 Integer<br />