994<br />

DSVG1P<br />

Creates pseudo loads or scalar terms for p-elements in design sensitivity analysis<br />

Parameters:<br />

COUPMASS Input-integer-default=-1. Coupled mass generation flag.<br />

Remark:<br />

-1 Lumped<br />

0Coupled<br />

K6ROT Input-real-default=-1.0. Normal rotational stiffness factor for<br />

CQUAD4 and CTRIA3 elements.<br />

ALTSHAPE Input-integer-default=0. Specifies set of displacement functions in pelement<br />

analysis. ALTSHAPE=0 selects the MacNeal set and 1 selects<br />

the Full Product Space set.<br />

WTMASS Input-real-default=-1.0. Specifies scale factor on structural mass<br />

matrix.<br />

NOPSLG Input-integer-default=0. Pseudo-load generation flag. Set to -1 if no<br />

load generation is requested for the current superelement based on<br />

the SEDV Case Control command.<br />

OPTFLG Input-integer-default=0. DSVG1P application method:<br />

1Statics<br />

2Normal modes<br />

3 Acceleration load<br />

UNUSED7 Input-integer-default=0. Unused.<br />

If NOPSLG ≠<br />

0 , then a null EGX matrix is generated.