OBC Output contact pressure and traction results<br />

OBC<br />

Output contact pressure and traction results<br />

For SOL 101 (linear contact), SOL 601, 106 and SOL 601,129, SORT1 only.<br />

Record 0 – HEADER<br />

Word Name Type Description<br />

1 NAME(2) CHAR4 Data block name,e.g. OBC1<br />

Record 1 – IDENT<br />

Word Name Type Description<br />

1 ACODE I Device code + 10* Approach Code<br />

2 TCODE I Table code, 62<br />

3 UNDEF None<br />

4 SUBCASE I<br />

5 TIME RS Time Step<br />

6-7 UNDEF None<br />

8 LOADSET I Load Set or Zero<br />

9 FCODE I 1<br />

10 NUMWDE I Number of words per entry in DATA record<br />

11-50 UNDEF None<br />

51 TITLE(32) CHAR4 Title<br />

83 SUBTITL(32) CHAR4 Subtitle<br />

115 LABEL(32) CHAR4 Label<br />