11.01.2013 Views

NX Nastran DMAP Programmer's Guide - Kxcad.net

NX Nastran DMAP Programmer's Guide - Kxcad.net

NX Nastran DMAP Programmer's Guide - Kxcad.net

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Record 13 – MOMENT2(4701,47,23)<br />

GEOM3<br />

Table of Bulk Data entry images related to static and thermal loads<br />

Word Name Type Description<br />

1 SID I Load set identification number<br />

2 G I Grid point identification number<br />

3 M RS Moment scale factor<br />

4 G(4) I Grid point identification numbers<br />

Record 14 – PLOAD(5101,51,24)<br />

Word Name Type Description<br />

1 SID I Load set identification number<br />

2 P RS Pressure<br />

3 G(4) I Grid point identification numbers<br />

Record 15 – PLOAD1(6909,69,198)<br />

Word Name Type Description<br />

1 SID I Load set identification number<br />

2 EID I Element identification number<br />

3 TYPE I Load type<br />

4 SCALE I Scale factor for X1 and X2<br />

5 X1 RS Distance to position 1 along the element<br />

axis from end A<br />

6 P1 RS Pressure at position 1<br />

7 X2 RS Distance to position 2 along the element<br />

axis from end A<br />

8 P2 RS Pressure at position 2<br />

Record 16 – PLOAD2(6802,68,199)<br />

Word Name Type Description<br />

1 SID I Load set identification number<br />

265