SSG1<br />

Computes static load matrix<br />

TABS Input-real-default=0.0. Absolute temperature conversion. For example,<br />

set to 273.16 when specifying temperatures in Celsius or 459.69 in<br />

Fahrenheit.<br />

SEID Input-integer-default=0. Superelement identification number.<br />

Remarks:<br />

1. One static load is built for each CASECC record starting with NSKIP + 1 as long<br />

as the boundary conditions are constant. IF NSKIP ≤ 0, it is set to zero.<br />

2. In SLTH the heat transfer loads REFERENCING ELEMENTS (QVOL, QBDY1,<br />

QBDY2, QBDY3 and QVECT Bulk Data entries) have been converted to applied<br />

load factors and connected grid points.<br />

3. SLT and BGPDT cannot be purged if external static loads or LOAD Bulk Data<br />

entries are selected in CASECC.<br />

4. CSTM cannot be purged if any grid point or load references a coordinate system<br />

other than basic.<br />

5. EST and MPT cannot be purged if thermal or element deformation loads are<br />

selected.<br />

6. ETT cannot be purged if thermal loads are applied.<br />

7. EDT cannot be purged if element deformation loads are selected.<br />

8. MGG cannot be purged if GRAV or RFORCE loads are applied.<br />

9. DIT cannot be purged if temperature-dependent materials are present.<br />

10. UG may be purged, but geometric nonlinear effects will be ignored.<br />

11. PTELEM may be purged.<br />

12. CSTM0 and SCSTM are required to support the MB=-1 on the GRAV and<br />

RFORCE Bulk Data entries.<br />