Guide Specification<br />

2. Card Readers <strong>and</strong> Card Readers with Keypads shall be compatible with LAX HID issued<br />

identification <strong>and</strong> access control cards, <strong>and</strong> shall be compatible HID 13.56 MHz<br />

Contactless Smart Card technologies.<br />

H. Card Reader<br />

1. HID model R40 ( no substitutions)<br />

2. The firmware shall support both HID I class <strong>and</strong> PIV card formats<br />

I. Card Reader with Keypad<br />

1. HID model RK40 ( no substitutions)<br />

2. The firmware shall support both HID I class <strong>and</strong> PIV card formats<br />

J. Door Position Switches (Alarm Contacts)<br />

1. Door Position Switches shall be compatible with the door style <strong>and</strong> door materials<br />

2. Door Position Switches shall be magnetic activated <strong>and</strong> shall be flush mounted wherever<br />

possible<br />

3. Flush Mount<br />

a. GE 1078/1076 Series, or approved equal<br />

4. Surface Mount<br />

K. Alarm Horns<br />

a. Surface mounted Door Position Switches shall be high security triple-biased<br />

devices.<br />

b. GE 2700 Series, or approved equal<br />

1. Alarm Horns shall be installed as indicated in the drawings<br />

2. Alarm Horns shall be installed at a height <strong>and</strong> in a manner consistent with existing alarms<br />

horns installed in the TBIT<br />

a. Alarm Horns shall be connected to the output interface module provided in the<br />

door’s associated GE M3000 access control panel<br />

3. Interior Alarm Horns<br />

a. System Sensor MHW, or approved equal<br />

4. Exterior Alarm Horns<br />

ACCESS CONTROL AND ALARM MONITORING SYSTEM (ACAMS)<br />

REQUIREMENTS<br />

28 13 00 - 15<br />

Security Systems