shall be provided. In addition to steel windows, panels of suitable size to suit the<br />

architectural treatment and made of translucent sheets of polycarbonate material shall also<br />

be provided d on the side cladding for natural lighting.<br />

4.4 Control building, M. C. C. Buildings<br />

These shall be R. C. C. framed structures with columns, beams, slabs and foundations etc.<br />

Cladding shall be of brickwork with plastering on both sides. Roof shall be pro provided with roof<br />

water proofing treatment, as specified elsewhere in the Technical specification. In case of<br />

control building suitable permanent interconnection shall be provided at appropriate level<br />

with the existing respective buildings. All air - conditioned oned areas, shall be provided with the<br />

suspended permanently colour coated aluminium false ceiling system (details specified<br />

elsewhere). Adequate aluminium doors and windows shall be provided for natural lighting,<br />

ventilation and view.<br />

4.5 Pump Houses<br />

These e shall be of R.C.C. or steel framed structure with columns, beams, slab andfoundations<br />

etc. cladding shall be of brick work with plastering on both sides. Roofshall be provided with<br />

roof water proofing treatment as specified elsewhere.Underground sump and water tanks<br />

shall be of R.C.C. Adequate number of doors,Windows and Rolling Shutters shall be<br />

provided.Galvanized steel ladder / rung ladder shall be provided for access to the roof level<br />

ofthe pump house and water tanks.<br />

4.6 Pent House<br />

These shall be of R. C. C. framed structures with columns, beams, slabs andfoundations etc.<br />

Cladding shall be of brickwork with plastering on both sides. Roofshall be provided with roof<br />

water proofing treatment as specified elsewhere. Adequate nos. of steel doors and window windows<br />

shall be provided for natural lighting and ventilation.<br />

4.7 Toilets<br />

Toilet with potable water line facilities shall be provided in each of the following locations:<br />

In all M. C. C. Rooms Control Building Each unit shall have brick enclosure, and the following<br />

fittings.<br />

i ) Squatting type, white, vitreous china Orissa 1 No. pattern, W.C. pan with high level<br />

flushing cistern ( C.I. ) and all requisite fittings<br />

ii ) Bowl type Urinal with automatic flushing 2 Nos. cistern ( C.I. ) and all requisite fittings<br />

iii ) Wash Basin 630 mm x 450 mm with 2 Nos.two taps and all requisite items<br />

iv ) Mirror 600 mm x 450 mm x 5.5 mm thick 2 Nos.with bevelled edges ( Superior sheet<br />

glass )<br />

v ) C.P. Brass Towel Rod 600 x 20 mm 1 No.<br />

vi ) Liquid Soap Container 2 Nos.<br />

vii ) Washing Tap ( CP Brass ) 2 Nos.<br />

viii ) Overhead Polyethylene water tank 1 No.(min. 500 litres capacity)<br />

ix ) Suitable provision for installation of water coolers.<br />

4.8 Staircase<br />

All roofs & floors of transfer houses shall be accessible through staircase. However,for the<br />

pump houses, access to the roof will be provided by cage ladder. All stairs other than those<br />

of M. C. C. rooms and control rooms shall be of steel (min (minimum imum 1000 mm wide)and<br />

maximum rise should not be more than 180 mm and minimum tread width 250 mm.<br />

Stringers shall be of rolled steel channel( minimum ISMC 250 )and tread shall be of steel<br />

gratings. Stairs shall be provided with 32 mm dia nominal bore mediu medium m duty M. S. pipe hand<br />

rail. Handrails (for staircases, around openings, in walkways etc.) shall be of standard weight<br />

steel pipe of flush welded constructions, ground smooth using 32 mm nominal bore medium<br />

class pipe provided with double rail, top rail ab about out 1.0 metre above platform level and pipe<br />

posts spaced not more than 1.5 metres apart. Angle handrail post may be provided when<br />

Technical Specification:Sec-7, Civil<br />

Page 5 of 21

Hooray! Your file is uploaded and ready to be published.