6. Equipment wise List of commissioning spares and consumables with item wise<br />

description and quantity included in the main offer.<br />

7. List of 2 years operation spares, equipment wise (un (un-priced). priced). The list shall indicate<br />

description and quantity for each item.<br />

8. List of special tools and tackles<br />

9. Work Schedule with bar chart indicating all activities for electrics.<br />

10. Phase-wise wise construction power requirements for erection / testing activities.<br />

11. Questionnaire as asked, duly filled filled-in.<br />

12. Reference list of similar jobs carried out<br />

13. Dimensional details & weights of each equipment offered (tentative)<br />

Technical Data to be submitted with the Bid.<br />

1. Name and capacity of MCC considered<br />

2. List of LT drives of each MCC along with single line diagrams<br />

3. Connected load and Maximum demand of each section of 33 kV switchboard/ 415 V PCC<br />

4. Connected load and Maximum demand of each section of MCC.<br />

5. List of motors with ratings ( working working+ + standby) 6. List of performance tests proposed by<br />

the tenderer to demonstrate the guaranteed parameters for the electrical equipments. 7.<br />

Specific energy consumption, maximum demand and annual energy consumption. 8.<br />

Type test certificates for major categ categories ories of equipment, issued by independent testing<br />

authority. 9. Technical catalogues of major equipment offered. 10. Services to be<br />

provided by owner at battery limit with specification 11. Single Line Diagram of each<br />

MCC/ DB 12. Capacity of UPS for stacke stacker r & reclaimer 13. Capacity of PLC for stacker &<br />

reclaimer 14. Size of HT/LT trailing cables considered 15. Rating of 33 kV on load isolators<br />

considered<br />

4.2 TECHNICAL PARTICULARS TO BE SUBMITTED BY THE BIDDER ALONG WITH THE BID<br />

GENERAL<br />

The information /data data asked under this section shall be furnished by the tenderer along with<br />

the offer. In the event of the contract being awarded , the data/technical particulars furnished<br />

here under and accepted by the owner shall be deemed to form a part of the contract contract.<br />

Design Considerations<br />

:<br />

1. List of Drives/ Mechanism with kW Rating :<br />