12.4 DATA SHEET: DRIVE EQUIPMENT<br />

GENERAL<br />

12.4.1 Continuous Motor Rating (Name Plate Rating) at 50 Degree Centigrade Ambient temp. for<br />

Electric Motors<br />

a) For conveyors of belt conveyor systems and belt for In line magnetic separator:<br />

*120% 120% of actual power at drive motor output shaft at specified design capacity<br />

b) WT, SAC, apron feeders: *110% 110% of actual power requirement at drive motor output<br />

shaft at guaranteed (rated) capacity.<br />

c) Mono-rail rail hoists (travel and hoisting), various pumps of DS systems, service water<br />

systems, cooling water system, potable water system and sump pumps: *110% of<br />

actual power requirement at drive motor output shaft at guaranteed (rated)<br />

capacity.<br />

d) Ventilation Fans: *110% 110% of actual power requirement at drive motor output shaft at<br />

guaranteed (rated) capacity. In case of belt drive, the efficiency of transmission shall<br />

be considered as 95%.<br />

*The The actual power at drive motor output shaf shaft t shall be calculated after considering all the<br />

losses of down the line equipment’s of the drive train.<br />

1.0 Drive Equipment Rating<br />

a) For Conveyors : 120% of actual design requirement<br />

b) Other Equipment 1 x 100 % duty: 120% of actual design requirement<br />

c) ) Other Equipment 2 x 50 % duty: 110 % of actual design requirement<br />

2.0 DESIGN & CONSTRUCTION REQUIREMENT<br />

2.1.0 Gear Box<br />

2.1.1 Type<br />

(a) Below 40 KW: Helical, worm, bevel as per requirement without cooling coil<br />

(b) Above 40 KW: Helical / bevel helical wwithout<br />

cooling coil<br />

2.1.2 Service Factor: As per accepted engineering practice / manufacturer's<br />

recommendations<br />

2.1.3 Ambient temperature for Thermal rating: 50<br />

2.1.4 Mounting: On Machined/Ground Surfaces<br />

2.1.5 Output Rating:<br />

a) For belt conveyor systems<br />

requirement at drive pulley shaft at design capacity}<br />

b) For other equipment<br />

of the driven equipment }<br />

@ Service factor shall include all the components considered by the supplier and should be<br />

clearly indicated in manufacturer’s gear box selection catalogues.<br />

o 2.1.2 Service Factor: As per accepted engineering practice / manufacturer's<br />

C Minimum<br />

2.1.4 Mounting: On Machined/Ground Surfaces<br />

a) For belt conveyor systems @ Service factor X {1.2 times the actual power<br />

requirement at drive pulley shaft at design capacity}<br />

b) For other equipment @ Service factor X {1.2 times the actual power requirement<br />

of the driven equipment }<br />

shall include all the components considered by the supplier and should be<br />

clearly indicated in manufacturer’s gear box selection catalogues.<br />

2.1.6 Duty: 24 Hrs. Continuous<br />

2.2.0 Flexible Couplings:<br />

2.2.1 Type: Geared capacity.<br />

2.2.2 Rating: Not less than han motor rating.<br />

Technical Specification:Sec-4,System System Parameters, Operation & Control Philosophy<br />