2.1.3 Maximum Hoisting speed for electric hoists: 6 m/min<br />

2.1.4 Drive Motors: SQIM, Separate for travel & lift<br />

2.1.5 No. of starts for drive motor: 150 starts/hr at 40% CDF<br />

2.1.6 Wire Rope<br />

(i) Type/Construction: Pre Pre-formed formed type, hemp cored, regular lay 6/36 construction<br />

(ii) Breaking Strength: 160 160-175 kgf/sq. mm<br />

2.1.7 Bearing<br />

(i) Type: Ball/Roller bearing<br />

(ii) Life: 20 years<br />

2.1.8 Brake: Electro Mechanical type with asbestos lining.<br />

2.1.9 Load Hook: Swiveling type forged circular shank section.<br />

2.1.10 Duty: Class –2<br />

2.2.0 Monorail location/layout<br />

2.2.1 Cross section I beam<br />

2.2.2 Distance between CC/L<br />

/L of monorail & C.G. of equipment to be lifted Maximum 500<br />

mm<br />

2.2.3 Power Cables Support Festoon type arrangement<br />

2.3.0 Manual Hoists<br />

2.3.1 Maximum manual effort for operation. 30 Kg<br />

15.0 CHUTES AND HOPPERS<br />

15.1 GENERAL<br />

Chutes & Hoppers, flap gates and shall be furnished integral with coal handling system being<br />

supplied. All necessary accessories, electricals etc. shall be provided to ensure proper<br />

flow/storage/bifurcation of coal as per system requirements.<br />

15.1.1 CODES AND STANDARDS<br />

The design, gn, manufacture, inspection and testing of Chutes & Hoppers shall comply with all<br />

the currently applicable statutes, regulations and safety codes in the locality where the<br />

equipment is to be installed. The chutes, hoppers shall conform to the latest editio edition of the<br />

following standards and codes. Other internationally acceptable standards/codes, which<br />

ensure equal or higher performance than those specified, shall also be accepted. Nothing in<br />

this specification shall be construed to relieve the,contractor of tthe<br />

he required statutory<br />

responsibility. In case of any conflict in the standard and this specification, the decision of<br />

the Owner/RITES shall be final and binding.<br />

• IS:4682 :Code of practice for lining of vessels and equipment for chemical<br />

processes.<br />

• IS:226 : Structural Steel (Standard Quality)<br />

• IS:11592 : Code of practice for selection and design of Belt Conveyors.<br />

15.2 DESIGN AND CONSTRUCTION<br />

15.2.1 Chutes, Hoppers<br />

15.2.2 The minimum valley angle of chutes shall be 60 degrees from horizontal.<br />

Technical Specification:Sec-4,System System Parameters, Operation & Control Philosophy<br />