72<br />

<strong>Milk</strong> <strong>and</strong> dairy products <strong>in</strong> human nutrition<br />

figure 3.4<br />

Loss of vitam<strong>in</strong>s <strong>in</strong> milk associated with various heat treatments<br />

% loss<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Steril.<br />

UHT<br />

Past.<br />

Vitam<strong>in</strong> C Folate Thiam<strong>in</strong> Riboflav<strong>in</strong> Pyridox<strong>in</strong>e Vitam<strong>in</strong> B 12<br />

Sources: Sharma <strong>and</strong> Lal, 1998: Pasteurization at 63 °C for 30 m<strong>in</strong>utes <strong>and</strong> sterilization at 121 °C for 15 m<strong>in</strong>utes;<br />

Andersson <strong>and</strong> Öste, 1994: data for average values or most commonly reported values. Various conditions, <strong>in</strong>clud<strong>in</strong>g<br />

pasteurization at 72–75 °C for 15–20 seconds, pasteurization at 90–92 °C for 2–3 seconds; direct <strong>and</strong> <strong>in</strong>direct UHT<br />

treatment; Burton et al., 1970: UHT sterilization at 144 °C for direct heat<strong>in</strong>g <strong>and</strong> 141 °C for <strong>in</strong>direct heat<strong>in</strong>g; Haddad<br />

<strong>and</strong> Loewenste<strong>in</strong>, 1983: pasteurization at 72 °C for 16 seconds <strong>and</strong> 80 °C for 16 seconds, UHT sterilization at 110 °C for<br />

3.5 seconds <strong>and</strong> 140 °C for 3.5 seconds. References cited <strong>in</strong> Asadullah et al., 2010: sterilization at 143 °C for 3–4 seconds;<br />

<strong>in</strong>-bottle sterilization at 120 °C for 13 m<strong>in</strong>utes.<br />

cow milk, fortified with 256 mg of vitam<strong>in</strong> C/litre) subjected to heat treatment:<br />

after 1 month <strong>in</strong> storage, 51–99 percent of vitam<strong>in</strong> C had been degraded (Gliguem<br />

<strong>and</strong> Birlouez-Aragon, 2005). The almost total loss of vitam<strong>in</strong> C on storage (either<br />

UHT-processed or <strong>in</strong>-bottle sterilized) occurred when three-layered packag<strong>in</strong>g was<br />

used, while 51 percent degradation occurred with six-layered packag<strong>in</strong>g (Gliguem<br />

<strong>and</strong> Birlouez-Aragon, 2005).<br />

Not more than 10 percent loss <strong>in</strong> riboflav<strong>in</strong> was reported, <strong>in</strong>dependent of heat<br />

treatments used. Niac<strong>in</strong> <strong>and</strong> pantothenic acid were reported to be relatively stable<br />

dur<strong>in</strong>g UHT treatment (