3 Produce the report with the toggle report comm<strong>and</strong>..<br />

You can produce this same information using the coverage report comm<strong>and</strong> (CR-132).<br />

Toggle coverage UM-345<br />

Note: If you want to ensure that you are reporting all signals in the design, use the<br />

-nocollapse argument to vsim when you load your design. Without this argument, the<br />

simulator collapses certain ports that are connected to the same signal in order to improve<br />

performance, <strong>and</strong> those collapsed signals will not appear in the report. The -nocollapse<br />

argument degrades simulator performance, so it should be used only when it is absolutely<br />

necessary to see all signals in a toggle report.<br />