Preference variables located in INI files UM-531<br />

Variable name Value range Purpose Default<br />

CheckpointCompressMode 0, 1 if 1, checkpoint files are written in<br />

compressed format; this variable can be set<br />

interactively with the Tcl set comm<strong>and</strong><br />

Comm<strong>and</strong>History any valid<br />

filename<br />

ConcurrentFileLimit any positive<br />

integer<br />

CoverAtLeast any positive<br />

integer<br />

(UM-477)<br />

sets the name of a file in which to store the<br />

Main window comm<strong>and</strong> history<br />

controls the number of VHDL files open<br />

concurrently; this number should be less<br />

than the current limit setting for max file<br />

descriptors; 0 = unlimited<br />

the minimum number of times a functional<br />

coverage directive must evaluate to true<br />

CoverEnable 0, 1 if 1, all functional coverage directives in the<br />

current simulation are enabled<br />

CoverLimit any positive<br />

integer<br />

specifies the number of cover directive hits<br />

before the directive is auto disabled<br />

CoverLog 0, 1 turns on transcript logging for functional<br />

coverage directive counting<br />

CoverWeight natural integer<br />

(>=0)<br />

DatasetSeparator any character<br />

except those with<br />

special meaning<br />

(i.e., \, {, }, etc.)<br />

DefaultForceKind freeze, drive, or<br />

deposit<br />

DefaultRadix symbolic, binary,<br />

octal, decimal,<br />

unsigned,<br />

hexadecimal,<br />

ascii<br />

DefaultRestartOptions one or more of:<br />

-force,<br />

-noassertions,<br />

-nobreakpoint,<br />

-nolist, -nolog,<br />

-nowave<br />

the relative weighting for functional<br />

coverage directives<br />

the dataset separator for fully-rooted<br />

contexts, for example sim:/top; must not be<br />

the same character as PathSeparator<br />

defines the kind of force used when not<br />

otherwise specified; this variable can be set<br />

interactively with the Tcl set comm<strong>and</strong><br />

(UM-477)<br />

a numeric radix may be specified as a name<br />

or number (i.e., binary can be specified as<br />

binary or 2; octal as octal or 8; etc.); this<br />

variable can be set interactively with the Tcl<br />

set comm<strong>and</strong> (UM-477)<br />

sets default behavior for the restart<br />

comm<strong>and</strong><br />

on (1)<br />

commented<br />

out (;)<br />

40<br />

1<br />

1<br />

1<br />

on (1)<br />

1<br />

:<br />

drive for<br />

resolved<br />

signals;<br />

freeze for<br />

unresolved<br />

signals<br />

symbolic<br />

commented<br />

out (;)<br />