UM-378 14 - PSL Assertions<br />

Enabling/disabling failure <strong>and</strong> pass logging<br />

<strong>ModelSim</strong> <strong>SE</strong> User’s <strong>Manual</strong><br />

To enable or disable an assertion’s failure or pass logging from the GUI, right-click an<br />

assertion in the Assertions pane <strong>and</strong> select Failure Log or Pass Log. The selection acts as<br />

a toggle.<br />

To gain greater control over logging, right-click an assertion <strong>and</strong> select Change (or Edit ><br />

Advanced > Change from the menu bar). This opens the Change assertions dialog.<br />

Click here<br />

to enable/<br />

disable<br />

failure or<br />

pass<br />

logging<br />

See "Configure assertions dialog" (GR-114) for more details on this dialog.<br />

You can also enable or disable failure <strong>and</strong> pass logging using the assertion fail comm<strong>and</strong><br />

(CR-63) or the assertion pass comm<strong>and</strong> (CR-65), respectively.