24.03.2013 Views

ModelSim SE User's Manual - Electrical and Computer Engineering

ModelSim SE User's Manual - Electrical and Computer Engineering

ModelSim SE User's Manual - Electrical and Computer Engineering

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

UM-534 B - <strong>ModelSim</strong> variables<br />

Variable name Value range Purpose Default<br />

Startup = do ; any<br />

valid macro (do)<br />

file<br />

<strong>ModelSim</strong> <strong>SE</strong> User’s <strong>Manual</strong><br />

specifies the <strong>ModelSim</strong> startup macro; see<br />

the do comm<strong>and</strong> (CR-151)<br />

StdArithNoWarnings 0, 1 if 1, warnings generated within the<br />

accelerated Synopsys std_arith packages<br />

are suppressed; this variable can be set<br />

interactively with the Tcl set comm<strong>and</strong><br />

TranscriptFile any valid<br />

filename<br />

file for saving comm<strong>and</strong> transcript;<br />

environment variables may be included in<br />

the pathname<br />

UnbufferedOutput 0, 1 controls VHDL <strong>and</strong> Verilog files open for<br />

write; 0 = Buffered, 1 = Unbuffered<br />

UseCsupV2 0, 1 instructs vsim to use /usr/lib/libCsup_v2.sl<br />

for shared object loading; for use only on<br />

HP-UX 11.00 when you have compiled<br />

FLI/PLI/VPI C++ code with aCC's -AA<br />

option<br />

UserTimeUnit fs, ps, ns, us, ms,<br />

sec, or default<br />

Veriuser one or more valid<br />

shared object<br />

names<br />

specifies scaling for the Wave window <strong>and</strong><br />

the default time units to use for comm<strong>and</strong>s<br />

such as force (CR-180) <strong>and</strong> run (CR-252);<br />

should generally be set to default, in which<br />

case it takes the value of the Resolution<br />

variable; this variable can be set<br />

interactively with the Tcl set comm<strong>and</strong><br />

(UM-477)<br />

list of dynamically loadable objects for<br />

Verilog PLI/VPI applications; see<br />

Appendix D - Verilog PLI / VPI / DPI<br />

VoptFlow 0,1 if 1, <strong>ModelSim</strong> operates in optimized mode<br />

rather than debug mode<br />

WaveSignalNameWidth 0, positive<br />

integer<br />

controls the number of visible hierarchical<br />

regions of a signal name shown in the<br />

"Wave window" (GR-211); the default value<br />

of zero displays the full name, a setting of<br />

one or above displays the corresponding<br />

level(s) of hierarchy<br />

WLFCollapseMode 0, 1, 2 if 0, WLF file records values at every<br />

change of the logged objects; if 1, WLF file<br />

records values only at the end of each delta<br />

step; if 2, WLF file records values only at<br />

the end of a simulator time step<br />

commented<br />

out (;)<br />

off (0)<br />

transcript<br />

0<br />

off (0)<br />

default<br />

commented<br />

out (;)<br />

off (0)<br />

0<br />

1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!