Query q-bride MIB object, dot1qVlanStaticEgressPorts<br />

In <strong>the</strong> SNMP query below, all <strong>the</strong> Layer 2 ports in line card 0, 1, and 2 belonged to <strong>the</strong> default VLAN,<br />

VLAN 1. The .1107787777 is <strong>for</strong> VLAN 10 with no ports assigned.<br />

abcServer > snmpwalk -c public 172.16.1.43 .1.3.6.1.2.1.17.7.1.4.3.1.2<br />

SNMPv2-SMI::mib-2.17.7.1.4.3.1.2.1107787777 = Hex-STRING:<br />

FF FF FF 00 00 00 00 00 00 00 00 00 FF FF FF 00<br />

00 00 00 00 00 00 00 00 FF FF FF 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 01 08 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00<br />

SNMPv2-SMI::mib-2.17.7.1.4.3.1.2.1107787786 = Hex-STRING:<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00<br />

Add tagged ports using SNMP Set<br />

In this example, port 1-24 (line card 0) are being assigned to VLAN 10 as tagged ports.<br />

Note: You must always specify dot1qVlanStaticEgressPorts and dot1qVlanStaticUntaggedPorts in<br />

a single SNMP Set operation. The SNMP Set operation fails if only one OIDC is specified.<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 101