Figure 205 is a sample output from <strong>the</strong> show sflow linecard command:<br />

Figure 205 show sflow linecard Command Example<br />

Specifying Collectors<br />

The sflow collector command allows identification of sFlow Collectors to which sFlow datagrams are<br />

<strong>for</strong>warded. The user can specify up to two sFlow collectors. If two Collectors are specified, <strong>the</strong> samples are<br />

sent to both.<br />

Collection through Management interface is supported on plat<strong>for</strong>m e.<br />

Polling Intervals<br />

.<br />

<strong>Force10</strong>#show sflow linecard 1<br />

Linecard 1<br />

Samples rcvd from h/w :165<br />

Samples dropped <strong>for</strong> sub-sampling :69<br />

Total UDP packets exported :77<br />

UDP packets exported via RPM :77<br />

UDP packets dropped :<br />

Command Syntax Command Mode Usage<br />

sflow collector ip-address<br />

agent-addr ip-address [number<br />

[max-datagram-size number] ] |<br />

[max-datagram-size number ]<br />

CONFIGURATION Identify sFlow collectors to which sFlow<br />

datagrams are <strong>for</strong>warded.<br />

Default UDP port: 6343<br />

Default max-datagram-size: 1400<br />

The sflow polling-interval command configures <strong>the</strong> polling interval <strong>for</strong> an interface in <strong>the</strong> maximum<br />

number of seconds between successive samples of counters to be sent to <strong>the</strong> collector. This command<br />

changes <strong>the</strong> global default counter polling (20 seconds) interval. You can configure an interface to use a<br />

different polling interval.<br />

The polling interval can be configured globally (in CONFIGURATION mode) or by interface (in<br />

INTERFACE mode) by executing <strong>the</strong> interval command:<br />

Command Syntax Command Mode Usage<br />

sflow polling-interval<br />

interval value<br />

CONFIGURATION<br />

or<br />

INTERFACE<br />

Change <strong>the</strong> global default counter polling interval.<br />

interval value—in seconds.<br />

Range: 15 to 86400 seconds<br />

Default: 20 seconds<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 307