Figure 481 Configuring a Reau<strong>the</strong>ntiction Period<br />

<strong>Force10</strong>(conf-if-gi-2/1)#dot1x reau<strong>the</strong>ntication interval 7200<br />

<strong>Force10</strong>(conf-if-gi-2/1)#dot1x reauth-max 10<br />

<strong>Force10</strong>(conf-if-gi-2/1)#do show dot1x interface gigabite<strong>the</strong>rnet 2/1<br />

802.1x in<strong>for</strong>mation on Gi 2/1:<br />

-----------------------------<br />

Dot1x Status: Enable<br />

Port Control: FORCE_AUTHORIZED<br />

Port Auth Status: UNAUTHORIZED<br />

Re-Au<strong>the</strong>ntication: Enable<br />

Untagged VLAN id: None<br />

Tx Period: 90 seconds<br />

Quiet Period: 120 seconds<br />

ReAuth Max: 10<br />

Supplicant Timeout: 30 seconds<br />

Server Timeout: 30 seconds<br />

Re-Auth Interval: 7200 seconds<br />

Max-EAP-Req: 10<br />

Auth Type: SINGLE_HOST<br />

Auth PAE State: Initialize<br />

Backend State: Initialize<br />

Auth PAE State: Initialize<br />

Configuring Timeouts<br />

If <strong>the</strong> supplicant or <strong>the</strong> au<strong>the</strong>ntication server is unresponsive, <strong>the</strong> au<strong>the</strong>nticator terminates <strong>the</strong><br />

au<strong>the</strong>ntication process after 30 seconds by default. This amount of time that <strong>the</strong> au<strong>the</strong>nticator waits <strong>for</strong> a<br />

response can be configured.<br />

To terminate <strong>the</strong> au<strong>the</strong>ntication process due to an unresponsive supplicant:<br />

Step Task Command Syntax Command Mode<br />

1 Terminate <strong>the</strong> au<strong>the</strong>ntication process due<br />

to an unresponsive supplicant.<br />

dot1x supplicant-timeout seconds<br />

Range: 1-300<br />

Default: 30<br />

To terminate <strong>the</strong> au<strong>the</strong>ntication process due to an unresponsive au<strong>the</strong>ntication server:<br />

INTERFACE<br />

Step Task Command Syntax Command Mode<br />

1 Terminate <strong>the</strong> au<strong>the</strong>ntication process due<br />

to an unresponsive au<strong>the</strong>ntication server.<br />

dot1x server-timeout seconds<br />

Range: 1-300<br />

Default: 30<br />

Re-au<strong>the</strong>ntication Enabled<br />

New Maximun Re-au<strong>the</strong>ntications<br />

New Re-au<strong>the</strong>ntication Period<br />

INTERFACE<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 683