Table 9 SNMP Traps and OIDs<br />

OID String OID Name Description<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.34 chAlarmMinorPS Trap generated when a power supply<br />

minor alarm is issued.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.35 chAlarmMinorPSClr Trap generated when a power supply<br />

minor alarm is cleared.<br />

Fan<br />

.1.3.6.1.4.1.6027.3.1.1.2.2.1.2 chSysFanTrayOperStatus Each entry in <strong>the</strong> chSysFanTrayTable<br />

includes a set of objects which describe <strong>the</strong><br />

status of a particular fan tray, as identified<br />

by <strong>the</strong> chSysFanTrayIndex.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.36 chAlarmMinorFanBad Trap generated on <strong>the</strong> E600 or E1200<br />

when <strong>the</strong> status of one or more fans<br />

changes to down and generates a minor<br />

alarm.<br />

An E300 does not generate a minor alarm<br />

as <strong>the</strong> system monitors only <strong>the</strong> overall<br />

status of <strong>the</strong> fan tray.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.21 chAlarmMinorFanBadClear Trap generated when a minor alarm on one<br />

or more fans is cleared.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.16 chAlarmFanTrayDown Trap generated when all fans are down<br />

and/or when <strong>the</strong> fan tray status changes to<br />

missing or down.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.20 chAlarmFanTrayClear Trap generated when <strong>the</strong> fan tray status<br />

changes to operational.<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 109