Show Commands<br />

<strong>Force10</strong>#sh running-config interface tengigabite<strong>the</strong>rnet 2/0 !<br />

interface TenGigabitE<strong>the</strong>rnet 2/0<br />

no ip address<br />

mtu 9252<br />

switchport<br />

no shutdown<br />

buffer-policy fsqueue<br />

<strong>Force10</strong>#sho buffer-profile detail interface tengigabite<strong>the</strong>rnet 2/0 Interface Te 2/0<br />

Buffer-profile fsqueue Dynamic buffer 100.00 (Kilobytes)<br />

Queue# Dedicated Buffer Buffer Packets<br />

(Kilobytes)<br />

0 100.00 100<br />

1 200.00 20<br />

2 300.00 30<br />

3 400.00 40<br />

4 9.38 256<br />

5 9.38 256<br />

6 9.38 256<br />

7 9.38 256<br />

<strong>Force10</strong>#show buffer-profile detail fp-uplink linecard 2 port-set 0 Linecard 2 Port-set 0<br />

Buffer-profile fsqueue Dynamic Buffer 100.00 (Kilobytes)<br />

Queue# Dedicated Buffer Buffer Packets<br />

(Kilobytes)<br />

0 100.00 100<br />

1 200.00 20<br />

2 300.00 30<br />

3 400.00 40<br />

4 9.38 256<br />

5 9.38 256<br />

6 9.38 256<br />

7 9.38 256<br />

<strong>Force10</strong>#show buffer-profile detail csf linecard 2 port-set 0 Linecard 2 Port-set 0<br />

Buffer-profile csqueue<br />

Queue# Dedicated Buffer Buffer Packets<br />

(Bytes)<br />

0 80 100<br />

1 160 20<br />

2 240 30<br />

3 400 40<br />

4 7680 255<br />

5 10240 255<br />

6 10240 255<br />

7 10240 255<br />

Sample <strong>Configuration</strong>s<br />

The two general types of network environments are sustained data transfers and voice/data. <strong>Force10</strong><br />

<strong>Networks</strong> recommends a single-queue approach <strong>for</strong> data transfers, as shown in Figure 503 <strong>for</strong> <strong>the</strong> C-<strong>Series</strong><br />

and Figure 504 <strong>for</strong> <strong>the</strong> S-<strong>Series</strong>. Figure 503 is a sample configuration <strong>for</strong> a C-<strong>Series</strong> 48-port line card that<br />

uses <strong>the</strong> default packet pointer values.<br />

716 C-<strong>Series</strong> Debugging and Diagnostics