In <strong>the</strong> EXEC mode, <strong>the</strong> show interfaces switchport command displays only interfaces in Layer 2 mode<br />

and <strong>the</strong>ir relevant configuration in<strong>for</strong>mation. The show interfaces switchport command (Figure 175)<br />

displays <strong>the</strong> interface, whe<strong>the</strong>r <strong>the</strong> interface supports IEEE 802.1Q tagging or not, and <strong>the</strong> VLANs to<br />

which <strong>the</strong> interface belongs.<br />

Figure 175 show interfaces switchport Command Example<br />

<strong>Force10</strong>#show interfaces switchport<br />

Name: GigabitE<strong>the</strong>rnet 13/0<br />

802.1QTagged: True<br />

Vlan membership:<br />

Vlan 2<br />

Name: GigabitE<strong>the</strong>rnet 13/1<br />

802.1QTagged: True<br />

Vlan membership:<br />

Vlan 2<br />

Name: GigabitE<strong>the</strong>rnet 13/2<br />

802.1QTagged: True<br />

Vlan membership:<br />

Vlan 2<br />

Name: GigabitE<strong>the</strong>rnet 13/3<br />

802.1QTagged: True<br />

Vlan membership:<br />

Vlan 2<br />

--More--<br />

Use <strong>the</strong> show ip interfaces brief command in <strong>the</strong> EXEC privilege mode to view which interfaces are in<br />

Layer 3 mode. In Figure , GigabitE<strong>the</strong>rnet 1/5 is in Layer 3 mode since it has an IP address assigned to it<br />

and its status is up.<br />

Figure 176 show ip interfaces brief Command Example (Partial)<br />

<strong>Force10</strong>#show ip interface brief<br />

Interface IP-Address OK? Method Status Protocol<br />

GigabitE<strong>the</strong>rnet 1/0 unassigned NO Manual administratively down down<br />

GigabitE<strong>the</strong>rnet 1/1 unassigned NO Manual administratively down down<br />

GigabitE<strong>the</strong>rnet 1/2 unassigned YES Manual up up<br />

GigabitE<strong>the</strong>rnet 1/3 unassigned YES Manual up up<br />

GigabitE<strong>the</strong>rnet 1/4 unassigned YES Manual up up<br />

GigabitE<strong>the</strong>rnet 1/5 10.10.10.1 YES Manual up up<br />

GigabitE<strong>the</strong>rnet 1/6 unassigned NO Manual administratively down down<br />

GigabitE<strong>the</strong>rnet 1/7 unassigned NO Manual administratively down down<br />

GigabitE<strong>the</strong>rnet 1/8 unassigned NO Manual administratively down down<br />

Use <strong>the</strong> show interfaces configured command in <strong>the</strong> EXEC privilege mode to view only configured<br />

interfaces. In Figure 176, GigabitE<strong>the</strong>rnet 1/5 is in Layer 3 mode since it has an IP address assigned to it<br />

and its status is up.<br />

For details on <strong>the</strong> command syntax options and <strong>the</strong> fields displayed in <strong>the</strong> output of <strong>the</strong>se show interfaces<br />

commands, see <strong>the</strong> Interfaces chapter in <strong>the</strong> <strong>FTOS</strong> Command Reference.<br />

272 Interfaces