Recovering from a Failed Power Supply<br />

If ports are PoE-enabled, and a PSU fails, power might be terminated on some ports to compensate <strong>for</strong> <strong>the</strong><br />

power loss. This does not affect PoE individual port configurations.<br />

For C-<strong>Series</strong>, use <strong>the</strong> show power supply command to display PSU status (Figure 453).<br />

For S-<strong>Series</strong>, see <strong>the</strong> Power over E<strong>the</strong>rnet (PoE) chapter in <strong>the</strong> <strong>FTOS</strong> Command Reference <strong>for</strong> <strong>the</strong> S-<strong>Series</strong><br />

<strong>for</strong> an example of <strong>the</strong> output of <strong>the</strong> show power inline output and its field descriptions.<br />

Figure 453 show power supply Command Example on C-<strong>Series</strong><br />

R1#show power supply<br />

Power Model<br />

Supply Number Type Status<br />

------------------------------------------------<br />

PS0 -- -- Absent<br />

PS1 CC-C300-PWR-AC AC Active<br />

PS2 CC-C300-PWR-AC AC Fail<br />

PS3 CC-C300-PWR-AC AC Remote Off<br />

PS4 -- -- Absent<br />

PS5 -- -- Absent<br />

PS6 -- -- Absent<br />

PS7 -- -- Absent<br />

R1#<br />

If power must be terminated <strong>for</strong> some ports, <strong>the</strong> order in which ports are affected is based on priority. Ports<br />

with <strong>the</strong> lowest priority are terminated first (see Managing Power Priorities on page 646).<br />

Figure 454 Order of PoE Termination<br />

For <strong>the</strong> C-<strong>Series</strong> configuration in Figure 451:<br />

0<br />

1<br />

2<br />

Terminate PoE<br />

• Power <strong>for</strong> ports 7/1 and 7/2 is terminated first because it is configured with inline power auto.<br />

• Power <strong>for</strong> port 7/2 is terminated be<strong>for</strong>e PoE <strong>for</strong> port 7/1 because port 7/1 has a lower port number.<br />

• Power <strong>for</strong> port 7/0 is terminated last because it is configured with inline power static.<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 647