Version Compatibility between RPMs<br />

The system checks to ensure <strong>the</strong> high availability compatibility of <strong>the</strong> software images on <strong>the</strong> two RPMs.<br />

Images are compatible only if <strong>the</strong> first two digits of <strong>the</strong> version number match. If <strong>the</strong>y do not, an error<br />

message is displayed. View <strong>the</strong> loaded versions of <strong>FTOS</strong> on <strong>the</strong> RPMs using <strong>the</strong> command show<br />

redundancy (Figure 266).<br />

Message 21 <strong>FTOS</strong> Version Incompatibility Error<br />

************************************************<br />

*<br />

* Warning !!! Warning !!! Warning !!!<br />

*<br />

* ----------------------------------------------<br />

*<br />

* Incompatible SW Version detected !!<br />

*<br />

* This RPM -> E7-5-1-71<br />

* Peer RPM -> E7-5-1-56<br />

*<br />

************************************************<br />

Aug 6 18:39:33: %RPM0-P:CP %IRC-4-IRC_VERSION: Current RPM E7-5-1-71 Peer RPM E7-5-1-56 -<br />

Different software version detected<br />

Figure 266 Version Incompatibility in show redundancy Command<br />

<strong>Force10</strong>#show redundancy<br />

-- RPM Status --<br />

------------------------------------------------<br />

RPM Slot ID: 0<br />

RPM Redundancy Role: Primary<br />

RPM State: Active<br />

RPM SW Version: 7.5.1.0<br />

Link to Peer: Up<br />

-- PEER RPM Status --<br />

------------------------------------------------<br />

RPM State: Standby<br />

RPM SW Version: 7.4.1.0<br />

Second RPM online as standby<br />

Since <strong>the</strong> RPM on <strong>the</strong> C-<strong>Series</strong> also contains <strong>the</strong> switch fabric, even though <strong>the</strong> second RPM comes online<br />

as <strong>the</strong> standby, <strong>the</strong> switch fabric is active and is automatically available <strong>for</strong> routing. Change this behavior<br />

using <strong>the</strong> command offline sfm standby. To bring <strong>the</strong> secondary SFM online, issue <strong>the</strong> online sfm<br />

standby command. There is traffic loss anytime an SFM is brought online or taken offline. Use <strong>the</strong><br />

command show sfm all to determine <strong>the</strong> status of <strong>the</strong> SFMs on <strong>the</strong> RPMs.<br />