02.10.2013 Views

FTOS Configuration Guide for the C-Series - Force10 Networks

FTOS Configuration Guide for the C-Series - Force10 Networks

FTOS Configuration Guide for the C-Series - Force10 Networks

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Figure 86 Port Monitoring <strong>Configuration</strong>s on <strong>the</strong> E-<strong>Series</strong><br />

Line Card 0 Line Card 1<br />

Monitor Session 0 MD MG<br />

Monitor Session 1<br />

Port-Pipe 0 Port-Pipe 1 Port-Pipe 0<br />

Port Monitoring on C-<strong>Series</strong> and S-<strong>Series</strong><br />

The C-<strong>Series</strong> and S-<strong>Series</strong> support multiple source-destination statements in a monitor session, but <strong>the</strong>re<br />

may only be one destination port in a monitoring session (Message 12).<br />

Message 12 One Destination Port in a Monitoring Session Error Message on C-<strong>Series</strong> and S-<strong>Series</strong><br />

% Error: Only one MG port is allowed in a session.<br />

The number of source ports <strong>FTOS</strong> allows within a port-pipe is equal to <strong>the</strong> number of physical ports in <strong>the</strong><br />

port-pipe, but <strong>FTOS</strong> allows a maximum of four destination ports per port-pipe (Message 13). A source port<br />

may only be monitored by one destination port (Message 14), but a destination port may monitor more<br />

than one source port. Given <strong>the</strong>se parameters, Figure 86 illustrates conceptually <strong>the</strong> possible port<br />

monitoring configurations on <strong>the</strong> C-<strong>Series</strong> and S-<strong>Series</strong>.<br />

Message 13 One Destination Port in a Monitoring Session Error Message on C-<strong>Series</strong> and S-<strong>Series</strong><br />

% Error: Exceeding max MG ports <strong>for</strong> this MD port pipe.<br />

Message 14 One Destination Port per Source Port Error Message<br />

% Error: MD port is already being monitored.<br />

MD MG<br />

Monitor Session 2 MD<br />

Monitor Session 3 MD<br />

Figure 87 Port Monitoring <strong>Configuration</strong>s on <strong>the</strong> C-<strong>Series</strong> and S-<strong>Series</strong><br />

Monitor Session 0<br />

Monitor Session 1<br />

MD<br />

MD<br />

MG<br />

MD MG<br />

Monitor Session 2<br />

Port-Pipe 0 Port-Pipe 1 Port-Pipe 0<br />

MD MG<br />

Line Card 0 Line Card 1<br />

MD<br />

MD MG<br />

Port-Pipe 1<br />

Port-Pipe 1<br />

Port Monitoring 002<br />

Port Monitoring 003<br />

176 Port Monitoring