Replacing an Existing Line Card<br />

When a line card is replaced with ano<strong>the</strong>r, <strong>the</strong> system checks to ensure that <strong>the</strong> line card type is identical. If<br />

it is not, a mismatch error message (Message 20) is displayed. To clear this error and bring <strong>the</strong> card online,<br />

re-issue <strong>the</strong> linecard command, as shown in Figure 263.<br />

Figure 264 Replacing an Exising Line Card<br />

<strong>Force10</strong>#show linecard all<br />

-- Line cards --<br />

Slot Status NxtBoot ReqTyp CurTyp Version Ports<br />

---------------------------------------------------------------------------<br />

0 online online E48VB E48VB 7-5-1-71 48<br />

1 online online E48VB E48VB 7-5-1-71 48<br />

%RPM1-P:CP %CHMGR-2-CARD_DOWN: Line card 0 down - card removed<br />

%RPM1-P:CP %CHMGR-5-CARDDETECTED: Line card 0 present<br />

%RPM1-P:CP %CHMGR-3-CARD_MISMATCH: Mismatch: line card 0 is type EX8PB - type E48VB required<br />

Inserting a Second RPM<br />

The C-<strong>Series</strong> system is functional with only one RPM. If a second RPM is inserted, it comes online as <strong>the</strong><br />

standby RPM.<br />

Figure 265 Inserting a Second RPM into an Operational System<br />

<strong>Force10</strong>#show rpm all<br />

Line card removed,<br />

Replacement detected,<br />

Mismatch Error<br />

-- Route Processor Modules --<br />

Slot Status NxtBoot Version<br />

---------------------------------------------------------------------------<br />

0 active online 7-5-1-71<br />

1 not present<br />

%RPM0-P:CP %POLLMGR-2-ALT_RPM_STATE: Alternate RPM is present<br />

%RPM0-P:CP %IRC-6-IRC_COMMUP: Link to peer RPM is up<br />

%RPM1-S:CP %RAM-5-RPM_STATE: RPM1 is in Standby State<br />

<strong>Force10</strong>#show rpm all<br />

-- Route Processor Modules --<br />

Slot Status NxtBoot Version<br />

---------------------------------------------------------------------------<br />

0 active online 7-5-1-71<br />

1 standby online 7-5-1-71<br />

Second RPM online as standby<br />

Only <strong>the</strong> primary RPM au<strong>the</strong>nticates <strong>the</strong> user, <strong>the</strong> standby RPM does not support client/server<br />

au<strong>the</strong>ntication protocols such as RADIUS or TACACS+.<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 381