Table 77 SNMP Traps and OIDs<br />

OID String OID Name Description<br />

Power Supply Unit<br />

.1.3.6.1.4.1.6027.3.1.1.2.1.1.2 chSysPowerSupplyOperStatus Each entry in <strong>the</strong> chSysPowerSupplyTable<br />

includes a set of objects which describe <strong>the</strong><br />

status of a particular power supply.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.13 chAlarmPowerSupplyDown Trap generated when <strong>the</strong> power supply status<br />

changes to non-operational<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.17 chAlarmPowerSupplyClear Trap generated when <strong>the</strong> power supply status<br />

changes to operational.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.32 chAlarmMajorPS Trap generated when a power supply major<br />

alarm is issued<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.33 chAlarmMajorPSClr Trap generated when a power supply major<br />

alarm is cleared<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.34 chAlarmMinorPS Trap generated when a power supply minor<br />

alarm is issued<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.35 chAlarmMinorPSClr Trap generated when a power supply minor<br />

alarm is cleared<br />

Fan Tray<br />

.1.3.6.1.4.1.6027.3.1.1.2.2.1.2 chSysFanTrayOperStatus Each entry in <strong>the</strong> chSysFanTrayTable includes<br />

a set of objects that describe <strong>the</strong> status of a<br />

particular fan tray, as identified by <strong>the</strong><br />

chSysFanTrayIndex<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.36 chAlarmMinorFanBad Trap generated when <strong>the</strong> status of one or more<br />

fans changes to down, and generates a minor<br />

alarm<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.21 chAlarmMinorFanBadClear Trap generated when <strong>the</strong> minor alarm on <strong>the</strong><br />

one or more fans is cleared<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.16 chAlarmFanTrayDown Trap generated when all fans are down and/or<br />

when <strong>the</strong> fan tray status changes to missing or<br />

down<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.20 chAlarmFanTrayClear Trap generated when all fans and/or <strong>the</strong> fan<br />

tray status changes to operational<br />

Offline Diagnostics<br />

Note: As <strong>the</strong> SFM on <strong>the</strong> C-<strong>Series</strong> is a logical concept only, <strong>the</strong> FORCE10-CHASSIS-MIB SFM-related<br />

SNMP alarms and traps are not used.<br />

The offline diagnostics test suite is useful <strong>for</strong> isolating faults and debugging hardware.<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 705