02.10.2013 Views

FTOS Configuration Guide for the C-Series - Force10 Networks

FTOS Configuration Guide for the C-Series - Force10 Networks

FTOS Configuration Guide for the C-Series - Force10 Networks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Step Task<br />

4 Assign port 0/0-23 as untagged and <strong>the</strong> rest of <strong>the</strong> ports 1/0-23, 2/0-23 are tagged to<br />

VLAN10.<br />

snmpset -c public 123.45.6.78 .1.3.6.1.2.1.17.7.1.4.3.1.2.1107787786 x "FF<br />

FF FF 00 00 00 00 00 00 00 00 00 FF FF FF 00 00 00 00 00 00 00 00 00 FF FF<br />

FF" .1.3.6.1.2.1.17.7.1.4.3.1.4.1107787786 x "FF FF FF"<br />

5 The SNMP query now displays:<br />

snmpwalk -c public 123.45.6.78 .1.3.6.1.2.1.17.7.1.4.3.1.2.1107787786<br />

SNMPv2-SMI::mib-2.17.7.1.4.3.1.2.1107787786 = Hex-STRING:<br />

FF FF FF 00 00 00 00 00 00 00 00 00 FF FF FF 00<br />

00 00 00 00 00 00 00 00 FF FF FF 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00<br />

snmpwalk -c public 123.45.6.78 .1.3.6.1.2.1.17.7.1.4.3.1.4.1107787786<br />

SNMPv2-SMI::mib-2.17.7.1.4.3.1.4.1107787786 = Hex-STRING:<br />

FF FF FF 00 00 00 00 00 00 00 00 00 00 00 00 00 ? Port 1 – 24 are untagged<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />

00 00 00 00 00 00 00 00 00<br />

6 Execute <strong>the</strong> <strong>FTOS</strong> show vlan command:<br />

<strong>Force10</strong># show vlan<br />

Codes: * - Default VLAN, G - GVRP VLANs<br />

NUM Status Q Ports<br />

* 1 Inactive<br />

10 Inactive U Gi 0/0-23? port 0-23 as untagged<br />

T Gi 1/0-23<br />

T Gi 2/0-23<br />

104 Simple Network Management Protocol (SNMP)